Related Experiment Video
Updated: Jun 18, 2025

High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Quantitative analysis of the impurities in Etimicin using hydrophilic interaction liquid chromatography coupled with
Jiarui Gao1, Quan Wang2, Xinyi Wei3
1Collaborative Innovation Center of Yangtze River Delta Region Green Pharmaceuticals, Zhejiang University of Technology, Hangzhou 310014, China.
Abstract:
Etimicin is a typical aminoglycoside antibiotic (AG). High performance liquid chromatography-evaporation light scattering detector (HPLC-ELSD) method is a commonly used method for determining impurities in Etimicin. However, due to the poor reproducibility, low sensitivity and narrow linear range of the ELSD, high-throughput quantitative analysis of impurities in Etimicin currently poses a challenge. In this study, a sensitive method using hydrophilic interaction liquid chromatography coupled with charged aerosol detector (HILIC-CAD) was developed for the analysis of the impurities in Etimicin. The liquid phase conditions for determination impurities in Etimicin were optimized using Box Behnken design (BBD) and response surface methodology (RSM), resulting in satisfactory separation and optimal CAD output signal. We also studied the influence of CAD parameters on the signal-to-noise ratio and linearity of Etimicin and its impurities. This method has also been proven to be effective in separating impurities from two other typical AGs, Isepamicin and Amikacin. In the method validation, the coefficient of determination (R2) of Etimicin, Isepamicin and Amikacin and their impurities were all greater than 0.999, within the range of 0.5-50 μg/mL. The average recoveries of the impurities of three typical AGs were 99.03 %-101.22 %, RSDs all were less than 2.5 % for intra-day and inter-day precision, with good precision and accuracy. The developed HILIC-CAD quantification method was sensitive, accurate and highly selective for quantitative analysis of impurities in the AGs without need ion-pairing reagents, which is ensure the public medication safety. The method is first reported application of HILIC-CAD method for quantitative analysis of the impurities in AGs.
Related Concept Videos
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Ion-Exchange Chromatography
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Types of Detectors
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Chemical Ionization (CI) Mass Spectrometry