Related Experiment Video
Updated: Jun 18, 2025

Large Scale Non-targeted Metabolomic Profiling of Serum by Ultra Performance Liquid Chromatography-Mass Spectrometry UPLC-MS
Published on: March 14, 2013
Sample-Specific MS/MS Methods in High-Throughput Mass Spectrometry
David M Cox1, Xuejiao Yin2, Jahangir Alam3
1SCIEX, Concord, Ontario L4K 4V8, Canada.
Abstract:
The drug discovery process increasingly relies on high-throughput sample analysis to accelerate the identification of viable drug candidates. Recently, chromatographic-free high-throughput mass spectrometry (HT-MS) technologies have emerged, significantly increasing sample readout speed and enabling the analysis of large sample sets. These HT-MS platforms continuously acquire data from various samples into a single data file, presenting challenges in applying distinctive data acquisition methods to specific samples. This study introduces a novel approach that integrates real-time sample loading status to activate sample-specific MS/MS data acquisition methods on the high-throughput acoustic ejection mass spectrometry platform. Effective method switching and high signal reproducibility were demonstrated across different data acquisition window durations in multiple reaction monitoring (MRM), high-resolution MRM (MRMHR), and information-dependent acquisition modes. This advancement provides a user-friendly and robust solution to the method-setting challenges of HT-MS, expanding the implementation of HT-MS platforms in drug discovery and other high-throughput analytical applications.
More Related Videos
12:11Simultaneous Affinity Enrichment of Two Post-Translational Modifications for Quantification and Site Localization
Published on: February 27, 2020
10:37Deep Proteome Profiling by Isobaric Labeling, Extensive Liquid Chromatography, Mass Spectrometry, and Software-assisted Quantification
Published on: November 15, 2017
Related Concept Videos
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Tandem Mass Spectrometry
Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called collision-induced...
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
High-Resolution Mass Spectrometry (HRMS)
Mass Spectrometry: Overview
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...