Related Experiment Video
Updated: Jun 18, 2025

Author Spotlight: Unveiling the Potential of VSFG Microscopy in Studying Mesoscopically Heterogeneous Self-Assembled Structures
Published on: December 1, 2023
Angle-Resolved Linear Dichroism to Probe the Organization of Highly Ordered Collagen Biomaterials
Natacha Krins1, Frank Wien2, Margaux Schmeltz3
1Laboratoire de Chimie de la Matière Condensée de Paris (LCMCP), Sorbonne Université, CNRS, Paris F-75005, France.
Abstract:
Controlling the assembly of high-order structures is central to soft-matter and biomaterial engineering. Angle-resolved linear dichroism can probe the ordering of chiral collagen molecules in the dense state. Collagen triple helices were aligned by solvent evaporation. Their ordering gives a strong linear dichroism (LD) that changes sign and intensity with varying sample orientations with respect to the beam linear polarization. Being complementary to circular dichroism, which probes the structure of chiral (bio)molecules, LD can shift from the molecular to the supramolecular scale and from the investigation of the conformation to interactions. Supported by multiphoton microscopy and X-ray scattering, we show that LD provides a straightforward route to probe collagen alignment, determine the packing density, and monitor denaturation. This approach could be adapted to any assembly of chiral (bio)macromolecules, with key advantages in detecting large-scale assemblies with high specificity to aligned and chiral molecules and improved sensitivity compared to conventional techniques.
More Related Videos
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
X-ray Diffraction of Biological Samples
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal...
X-ray Crystallography
Diffraction
Diffraction is the change in the direction of travel experienced by an electromagnetic wave when it encounters a physical barrier whose dimensions are comparable to those of the wavelength of the light. X-rays are electromagnetic radiation with wavelengths about as long as the distance between neighboring...

