Abstract:
Current positive airway pressure devices cost NZ$800-$2500, posing a financial barrier for the estimated 1 billion individuals worldwide with sleep apnea and those researching respiratory diseases. Increasing diagnoses and research interest in the area necessitate a low-cost, easily accessible alternative. Thus, the mePAP, a high-quality, multipurpose, low-cost (∼NZ$250) positive airway pressure device, was designed and prototyped specifically for respiratory disease research, particularly for sleep apnea. The mePAP allows user customization and provides researchers with an affordable tool for testing positive airway pressure algorithms. Unlike typical commercial devices, the mePAP offers adaptability with open-source data collection and easily modifiable software for implementing and analysing different control and diagnostic algorithms. It features three control modes: constant; bilevel; and automatic; and provides pressures from 4 to 20 cmH2O, controlled via a phone app through Wi-Fi, with a mini-sensor added at the mask for increased accuracy. Validation tests showed the mePAP's performance is comparable to a gold-standard Fisher & Paykel device, with extremely similar output pressures. The mePAP's low cost enhances accessibility and equity, allowing researchers to test ventilation algorithms for sleep apnea and other respiratory conditions, with all data openly available for analysis. Its adaptability and multiple applications increase its usability and usefulness across various research and clinical settings.
Related Concept Videos
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation I: Indication and Settings
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...