Related Experiment Video
Updated: Jun 17, 2025

Guidelines for Elective Pediatric Fiberoptic Intubation
Published on: January 17, 2011
Prospective development and validation of a universal classification for paediatric videolaryngoscopic tracheal
Thorsten Dohrmann1, Nelly Gutsche1, Rilana Kramer1
1Department of Anaesthesiology, Centre of Anaesthesiology and Intensive Care Medicine, University Medical Centre Hamburg-Eppendorf, Hamburg, Germany.
Background:
The VIDIAC score, a prospectively developed universal classification for videolaryngoscopy, has shown excellent diagnostic performance in adults. However, there is no reliable classification system for videolaryngoscopic tracheal intubation in children. We aimed to develop and validate a multivariable logistic regression model and easy-to-use score to classify difficult videolaryngoscopic tracheal intubation in children and to compare it with the Cormack and Lehane classification. A secondary aim was to externally validate the VIDIAC score in children.
Methods:
We conducted a prospective observational study within a structured universal videolaryngoscopy implementation programme. We used C-MAC™ videolaryngoscopes in all children undergoing tracheal intubation for elective surgical procedures. We validated the VIDIAC score externally and assessed its performance. We then identified eligible co-variables for inclusion in the PeDiAC score, developed a multivariable logistic regression model and compared its performance against the Cormack and Lehane classification.
Results:
We studied 809 children undergoing 904 episodes of tracheal intubation. The VIDIAC score outperformed the Cormack and Lehane classification when classifying the difficulty of videolaryngoscopic tracheal intubation, with an area under the receiver operating characteristic curve of 0.80 (95%CI 0.73-0.87) vs. 0.69 (95%CI 0.62-0.76), respectively, p = 0.018. Eight eligible tracheal intubation-related factors, that were selected by 100-times repeated 10-fold cross-validated least absolute shrinkage selector operator regression, were used to develop the PeDiAC model. The PeDiAC model and score showed excellent diagnostic performance and model calibration. The PeDiAC score achieved significantly better diagnostic performance than the Cormack and Lehane classification, with an area under the receiver operating characteristic curve of 0.97 (95%CI 0.96-0.99) vs. 0.69 (95%CI 0.62-0.76), respectively, p < 0.001.
Conclusion:
We developed and validated a specifically tailored classification for paediatric videolaryngoscopic tracheal intubation with excellent diagnostic performance and calibration that outperformed the Cormack and Lehane classification.
Related Concept Videos
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Tracheostomy Suctioning I: Pre-Procedural Steps
Equipment Required