1State Key Laboratory for Diagnosis & Treatment of Infectious Diseases, National Clinical Research Center for Infectious Diseases, National Medical Center for Infectious Diseases, Collaborative Innovation Center for Diagnosis & Treatment of Infectious Diseases, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, Zhejiang, China.
Abstract:
Metagenomic next-generation sequencing (mNGS) in diagnosis of human brucellosis is comparatively unexplored. This report details five human brucellosis cases diagnosed using mNGS based on Illumina sequencing platform, comprising three females and two males, four with epidemiological exposure. In cases 1 and 2, plasma mNGS results showed one positive and one negative for Brucella melitensis, and subsequent blood cultures were both positive. Cases 3, 4 and 5 involved spinal brucellosis, some with paravertebral abscesses. mNGS from infectious tissue samples successfully detected Brucella, with read counts ranging between 30 and 1314, yet cultures were negative in cases 4 and 5. Following antibiotic and surgical treatments, all patients showed clinical improvement. This report shows mNGS testing enhances the detection sensitivity of brucellosis diagnosis.