Related Experiment Video
Updated: Jun 17, 2025

Database-guided Flow-cytometry for Evaluation of Bone Marrow Myeloid Cell Maturation
Published on: November 3, 2018
Advances in estimating plasma cells in bone marrow: A comprehensive method review
Ethan J Gantana1,2, Ernest Musekwa1,2, Zivanai C Chapanduka1,2
1Department of Pathology, Faculty of Medicine and Health Sciences, Stellenbosch University, Cape Town, South Africa.
Accurately quantifying bone marrow plasma cells is vital for diagnosing plasma cell neoplasms. While various methods exist, CD138 immunohistochemistry on biopsies offers the most reliable estimation for accurate diagnosis and treatment assessment.
Area of Science:
- Hematology
- Oncology
- Pathology
Background:
- Accurate plasma cell quantitation in bone marrow (BM) is essential for diagnosing plasma cell neoplasms.
- Current methods like BM aspirates, immunohistochemistry, and flow cytometry have limitations including patchy infiltration and sample dilution.
- Existing techniques yield variable results, with immunohistochemistry often showing higher plasma cell percentages than other methods.
Purpose of the Study:
- To provide a comprehensive review and comparison of methods for plasma cell estimation in bone marrow.
- To highlight the strengths and limitations of each technique.
- To guide the selection of optimal methods for accurate plasma cell estimation in clinical practice.
Main Methods:
- Review of existing literature on plasma cell quantitation methods.
- Comparison of Romanowsky-stained BM aspirates, immunohistochemistry (CD138, MUM1), flow cytometry, and radiological imaging.
- Exploration of emerging techniques including AI image analysis, dual-energy CT, radiomics, and molecular assays (qPCR, NGS).
Main Results:
- Immunohistochemically stained bone marrow biopsies consistently yield higher plasma cell percentages compared to Romanowsky-stained aspirates or flow cytometry alone.
- CD138 or MUM1 immunohistochemistry and AI image analysis show promise for accurate plasma cell identification and quantification.
- Radiological imaging and molecular techniques offer complementary diagnostic information but require further standardization.
Conclusions:
- No single gold standard method currently exists for bone marrow plasma cell quantitation.
- CD138-stained biopsies are favored for accurate estimation and are pivotal in diagnosing and monitoring multiple myeloma.
- Combining multiple methods (BM aspirate, biopsy, flow cytometry) enhances diagnostic accuracy for plasma cell neoplasms. Digital pathology is expected to advance laboratory medicine.
More Related Videos
09:57Comprehensive Protocol to Sample and Process Bone Marrow for Measuring Measurable Residual Disease and Leukemic Stem Cells in Acute Myeloid Leukemia
Published on: March 5, 2018
07:39Intracellular Phosphoflow Cytometry of Acute Myeloid Leukemia Patient-Derived Xenotransplants
Published on: June 6, 2025