Experimental and numerical study on the model of hybrid fiber phase change concrete frozen shaft wall
Related Experiment Video
Updated: Jun 17, 2025

Preparation of Aligned Steel Fiber Reinforced Cementitious Composite and Its Flexural Behavior
Published on: June 27, 2018
Dongwei Li1, Zhiwen Jia2, Zecheng Wang2
1College of Civil Engineering and Architecture, Dalian University, Dalian, China.
Abstract:
In this study, phase change materials (PCMs) were innovatively incorporated into hybrid fiber concrete. The properties of PCMs, which absorb and release heat during phase transitions, enable the concrete to actively respond to complex and varying temperature environments. This integration reduces the internal temperature differentials within the concrete, thereby preventing temperature-induced cracks in deep wellbore structures. Through the temperature control model test of the frozen shaft wall, it can be seen that the hybrid fiber phase change concrete (HFPCC) significantly reduces the internal temperature difference, and the maximum temperature difference along the radial direction is 35.84% lower than that of benchmark concrete (BC). The numerical simulation results indicate that a moderate phase transition temperature should be selected in engineering. The phase change temperature should not be close to the ambient temperature and peak temperature. The peak temperature can be reduced by 9.32% and the maximum radial temperature difference can be reduced by 30.89% by selecting an appropriate phase change temperature. The peak temperature and radial maximum temperature difference are both proportional to the latent heat of phase change. The temperature control performance of phase change concrete can be further improved by increasing the latent heat of phase change materials.
More Related Videos
05:26Determination of the Mechanical Properties of Flexible Connectors for Use in Insulated Concrete Wall Panels
Published on: October 19, 2022
06:27Expression of Cementitious Pore Solution and the Analysis of Its Chemical Composition and Resistivity Using X-ray Fluorescence
Published on: September 23, 2018
Related Concept Videos
Fiber Reinforced Concrete
Frost Resistant Concrete
Introducing microscopic air bubbles into the concrete mix through air entrainment creates small voids that accommodate ice expansion, thereby reducing internal pressures and preventing cracking. The optimal amount of...
Shrinkage in Concrete
When concrete is still in its plastic state, it can undergo a decrease in volume by about 1% of its absolute volume. This decrease is known as plastic shrinkage. It arises either...
Creep in Concrete
Cold Weather Concreting
To counteract the negative impacts of cold weather, ensuring...
Frost Action on Concrete
This freeze-thaw cycle primarily causes surface scaling, where...