Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Comprehensive two-dimensional gas chromatography using a miniaturized multiloop splitter-based non-cryogenic
Nuttanee Tungkijanansin1, Sornkanok Vimolmangkang2, Chadin Kulsing3
1Department of Chemistry, Faculty of Science, Chulalongkorn University, Bangkok 10330, Thailand.
Abstract:
Multiloop splitter-based non-cryogenic artificial trapping (M-SNAT) modulation technique was developed, miniaturized and applied in comprehensive two-dimensional gas chromatography (GC×GC) for analysis of cannabis samples. The approach employed deactivated fuse silica (DFS) columns configured into multiple loop splitter system halving the perimeters of the progressively upstream loops. This splitter device was located between the first (1D) semi-nonpolar column outlet and a microfluidic Deans switch (DS). Each splitter loop splits a peak into two subpeaks having the same area with different void times. Three loops were then applied resulting in the number of the split subpeaks (nsplit) of 8 for each peak, and retention time differences between any two adjacent subpeaks (∆tR,split) were the same. By applying periodic heartcut event (H/C) within every artificial modulation period (PAM) of nsplit×∆tR,split, comprehensive split-and-trapped modulation profiles of analytes could be selectively transferred onto the second (2D) polar column (30 m) without cryogen consumption. This artificial modulation system was applied for analysis of cannabis samples with enhanced 2D peak capacity (2nc∼15). The established method was applied to analyse cannabis extracts using vegetable oils with or without frying process. This reveals 454 different peaks with 76, 92, 35 and 70 specific components specifically observed by using olive oil extraction (OE), fried OE, coconut oil extraction (CE) and fried CE, respectively.
More Related Videos
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
05:31Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...