Performance Correction and Parameters Identification Considering Non-Uniform Electric Field in Cantilevered

Xianfeng Wang1,2, Hui Liu1,2, Huadong Zheng1,2

  • 1School of Civil Engineering and Architecture, Wuhan University of Technology, Wuhan 430070, China.

PubMed

Related Concept Videos

Determining Electric Field From Electric Potential01:12

Determining Electric Field From Electric Potential

The electric field and electric potential are related to each other. If the electric field at various points in the region of interest is known, it can be used to calculate the electric potential difference between any two points. Similarly, if the electric potential is known for various points, then it is possible to calculate the electric field.
In general, regardless of whether the electric field is uniform, it points in the direction of decreasing potential because the force on a positive...
4.6K
Potentiometer01:30

Potentiometer

Voltage and current measurements using a standard voltmeter and ammeter alter the circuit being measured either by drawing or resisting the current flow, which introduces uncertainties in the measurements. Null measurements balance the voltages so that no current flows through the measuring device and, therefore, no alterations occur in the measured circuit.
Suppose the emf of a battery needs to be measured. If the battery is directly connected to a standard voltmeter, the measured quantity is...
2.8K
Power Factor Correction01:20

Power Factor Correction

The power transmission to a factory involves the transfer of apparent power, a combination of active and reactive power. The power factor measures how effectively electrical power is converted into useful work output. The ratio of the real power (KW) that does the work to the apparent power (KVA) supplied to the circuit.
802
PI Controller: Design01:24

PI Controller: Design

Proportional Integral (PI) controllers are a fundamental component in modern control systems, widely used to enhance performance and mitigate steady-state errors. They are particularly effective in applications such as automatic brightness adjustment on smartphones, where they excel at mitigating steady-state errors for step-function inputs. Unlike PD controllers, which require time-varying errors to function optimally, PI controllers leverage their integral component to address residual...
1.6K
Control of Power Flow01:30

Control of Power Flow

There are several methods to control power flow in power systems:
865
Load-frequency control01:28

Load-frequency control

Load-frequency control (LFC) is vital for maintaining power system stability, ensuring that frequency and power flows remain within acceptable limits during load changes. Turbine-governor control eliminates rotor accelerations and decelerations following load changes. However, a steady-state frequency error persists when the change in the turbine-governor reference setting is zero. In an interconnected power system, each area agrees to export or import a scheduled amount of power through...