Related Experiment Video
Updated: Jun 17, 2025

Installation Method to Enhance Quality Control for Fiber Reinforced Polymer Spike Anchors
Published on: April 10, 2018
Evaluation of Bonding Behavior between Engineered Geopolymer Composites with Hybrid PE/PVA Fibers and Concrete
Yu Ling1, Xiafei Zhang1, Yanwei Wu1
1Guangzhou Power Supply Bureau, Guangdong Power Grid Co., Ltd., China Southern Power Grid Co., Ltd., Guangzhou 510620, China.
Abstract:
Engineered geopolymer composites (EGCs) exhibit excellent tensile ductility and crack control ability, making them promising for concrete structure repair. However, their widespread use is limited by high costs of reinforcement fiber and a lack of an EGC-concrete interface bonding mechanism. This study investigated a hybrid PE/PVA fiber-reinforced EGC using domestically produced unoiled PVA fibers to replace commonly used PE fibers. The bond performance of the EGC-concrete interface was evaluated through direct tensile and slant shear tests, focusing on the effects of PE fiber content (1%, 2%, and 3%), fiber hybrid ratios (2.0:0.0, 1.5:0.5, 1.0:1.0, 0.5:1.5, and 0.0:2.0), concrete substrate strength (C30, C50, and C70), and the ratio of fly ash (FA) to ground granulated blast furnace slag (GGBS) (6:4, 7:3, and 8:2) on interface bond strength. Results showed that the EGCs' compressive strength ranged from 77.1 to 108.9 MPa, with increased GGBS content significantly enhancing the compressive strength and elastic modulus. Most of the specimens exhibited strain-hardening behavior after initial cracking. Interface bonding tests revealed that a PE/PVA ratio of 1.0 increased tensile bond strength by 8.5% compared with using 2.0% PE fiber alone. Increasing the PE fiber content, PVA/PE ratio, GGBS content, and concrete substrate strength all improved the shear bond strength. This improvement was attributed to the flexible fibers' ability to restrict thermo-hydro damage and deflect and blunt microcracks, enhancing the interface's failure resistance. Cost analysis showed that replacing 50% of the PE fiber in EGC with unoiled PVA fiber reduced costs by 44.2% compared with PE fiber alone, offering the best cost-performance ratio. In summary, hybrid PE/PVA fiber EGC has promising prospects for improving economic efficiency while maintaining tensile ductility and crack-control ability. Future optimization of fiber ratios and interface design could further enhance its potential for concrete repair applications.
Related Concept Videos
Bonding and Strength of Aggregate
Fiber Reinforced Concrete
Abrasion Resistance of Concrete
One such test is the revolving disc test, where three plates...
Additives and Fillers in Concrete
The...
Pozzolans
Fly ash is...
Porosity in Cement Paste
The balance of water to cement in the mix is...