Related Experiment Video
Updated: Jun 17, 2025

Installation Method to Enhance Quality Control for Fiber Reinforced Polymer Spike Anchors
Published on: April 10, 2018
Influence of Polymer Fibre Reinforcement on Concrete Anchor Breakout Failure Capacity
Julia Spyra1,2, Nikolaos Mellios1, Michael Borttscheller3
1Faculty of Architecture and Civil Engineering, TU Dortmund University, 44227 Dortmund, Germany.
Polymer fibre reinforcement enhances concrete anchoring systems, increasing load resistance by 15-20% and ductility. This study provides new models for designing anchors in fibre-reinforced concrete, addressing a gap in current standards.
Area of Science:
- Civil Engineering
- Materials Science
- Structural Engineering
Background:
- Current anchoring system design standards do not cover fibre-reinforced concrete.
- Steel fibre reinforcement in concrete anchoring is gaining traction, but polymer fibre reinforcement is under-researched.
- Fastening technology in fibre-reinforced concrete is a growing area of scientific interest.
Purpose of the Study:
- To investigate the effects of polymer fibre reinforcement on concrete anchoring systems.
- To develop alternative models for assessing concrete breakout resistance in polymer fibre-reinforced concrete.
- To evaluate the load-bearing behavior of anchoring systems in polymer fibre-reinforced concrete under tensile loading.
Main Methods:
- Experimental evaluation of system load-bearing behavior under tensile loading, focusing on concrete breakout failure.
- Determining material properties of polymer fibre-reinforced concrete.
- Mathematical interpretation of material properties to propose new assessment models.
Main Results:
- Polymer fibres significantly enhance concrete's load-bearing capacity and ductility under tensile loads.
- The addition of polymer fibres resulted in a 15-20% increase in anchor load resistance.
- Failure displacements were observed to double, indicating significantly improved ductility.
Conclusions:
- Polymer fibre reinforcement transforms concrete's quasi-brittle response to a more ductile behavior.
- The findings support the development of standardized design procedures for anchoring systems in polymer fibre-reinforced concrete.
- This research provides a basis for improved safety and performance in structures utilizing fibre-reinforced concrete anchoring.