The role of protective liners and glass ionomer in managing pulp temperature during light curing
Vanessa-Dias-Barboza Munhoz1,2, Mateus-Garcia Rocha2, Americo-Bortolazzo Correr1
1Department of Restorative Dentistry, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil.
Background:
To evaluate the thermal insulation of protective liners and glass ionomer cement during light-curing procedures.
Material And Methods:
Human third molars underwent Class I preparations with dimensions 5 mm long × 4 mm wide × 4 mm deep in a standardized manner ensured a consistent ±0.5 mm dentin thickness at the pulpal floor. The teeth were attached to a customized oral cavity chamber simulator with a circulating bath at a standardized temperature of 34.2 ± 1oC. The temperature variations at the pulpal floor were captured in real-time by video using an infrared thermal camera (FLIR ONE Pro, FLIR Systems). The materials evaluated were: Dycal (Dentsply), TheraCal LC (Bisco), Activa (Pulpdent), and Fuji II LC (GC). All light-activation procedures were performed with the same light-curing unit (Valo Grand, Ultradent) in standard mode, 1000 mW/cm2, and time of exposure following manufacturer instructions. A power analysis was conducted to determine the sample size considering a minimal power of 0.8, with α=0.05. Statistical analyses were performed using ANOVA and Tukey's test for multiple comparisons.
Results:
The temperature at the pulpal floor increased above the 5.5 ºC safety threshold difference for clinical scenarios tested. None of the materials provided proper thermal insulation for light-curing procedures (p = 0.25). The higher the number of light-cured steps, the longer the pulp remained above the 5.5 ºC temperature threshold.
Conclusions:
The materials tested provided improper thermal insulation (Δ > 5.5 ºC). Thus, prolonged or multiple light-curing exposures can be harmful to the pulp tissues. Therefore, for indirect pulpal capping procedures, self-cured materials or a reduced number of steps requiring light curing must be adopted to reduce the amount of time the pulp remains above the 5.5 ºC safety temperature threshold. Key words:Dental Pulp Capping, Calcium hydroxide, Bioactive, Thermal Damage.
More Related Videos
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
16:30Application of Light-cured Dental Adhesive Resin for Mounting Electrodes or Microdialysis Probes in Chronic Experiments
Published on: July 30, 2007
Related Concept Videos
Accelerated Curing of Concrete
Masonry in Cold and Hot Weather Conditions
Other key practices include keeping masonry units...
Curing Methods
Hot Weather Concreting
Mitigating the heat increase in concrete can be economically achieved by shading aggregate stockpiles to prevent heating from solar radiation,...
Mass Concreting
To reduce the risk of such cracking, the concrete mix may incorporate low-heat cement and pozzolans to reduce the temperature rise. Pre-cooled angular aggregates and water-reducing admixtures...
Decreased Body Temperature