Related Experiment Video
Updated: Jun 17, 2025

Optimized Griess Reaction for UV-Vis and Naked-eye Determination of Anti-malarial Primaquine
Published on: October 11, 2019
Green highly sensitive and selective spectroscopic detection of guaifenesin in multiple dosage forms and spiked human
Neven N Mikawy1, Nancy Magdy1, Marwa H Mohamed2
1Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Ain Shams University, Abbassia, 11566, Cairo, Egypt.
Abstract:
Guaifenesin (GUA) is determined in dosage forms and plasma using two methods. The spectrofluorimetric technique relies on the measurement of native fluorescence intensity at 302 nm upon excitation wavelength "223 nm". The method was validated according to ICH and FDA guidelines. A concentration range of 0.1-1.1 μg/mL was used, with limit of detection (LOD) and quantification (LOQ) values 0.03 and 0.08 µg/mL, respectively. This method was used to measure GUA in tablets and plasma, with %recovery of 100.44% ± 0.037 and 101.03% ± 0.751. Furthermore, multivariate chemometric-assisted spectrophotometric methods are used for the determination of GUA, paracetamol (PARA), oxomemazine (OXO), and sodium benzoate (SB) in their lab mixtures. The concentration ranges of 2.0-10.0, 4.0-16.0, 2.0-10.0, and 3.0-10.0 µg/mL for OXO, GUA, PARA, and SB; respectively, were used. LOD and LOQ were 0.33, 0.68, 0.28, and 0.29 µg/mL, and 1.00, 2.06, 0.84, and 0.87 µg/mL for PARA, GUA, OXO, and SB. For the suppository application, the partial least square (PLS) model was used with %recovery 98.49% ± 0.5, 98.51% ± 0.64, 100.21% ± 0.36 & 98.13% ± 0.51, although the multivariate curve resolution alternating least-squares (MCR-ALS) model was used with %recovery 101.39 ± 0.45, 99.19 ± 0.2, 100.24 ± 0.12, and 98.61 ± 0.32 for OXO, GUA, PARA, and SB. Analytical Eco-scale and Analytical Greenness Assessment were used to assess the greenness level of our techniques.
More Related Videos
10:17High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
13:35A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
Related Concept Videos
Gas Chromatography: Types of Detectors-II
High-Performance Liquid Chromatography: Types of Detectors
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...