Related Experiment Video
Updated: Jun 17, 2025

Evaluation of Colorectal Cancer Risk and Prevalence by Stool DNA Integrity Detection
Published on: June 8, 2020
The repeat FIT (RFIT) study: Does repeating faecal immunochemical tests provide reassurance and improve colorectal
Nicholas G Farkas1,2, Lampros Palyvos1, James W O'Brien1
1Minimal Access Therapy and Training Unit (MATTU), Royal Surrey County Hospital NHS Foundation Trust, Guildford, UK.
Aim:
Faecal immunochemical tests (FIT) are highly sensitive for colorectal cancer (CRC) detection. Little evidence exists regarding repeat FIT. The repeat FIT (RFIT) study aimed to determine whether second and third FIT provide reassurance and improve CRC or significant bowel disease (SBD) identification.
Methods:
This was a prospective observational study. Patients recruited from urgent referrals returned three FIT and underwent colonoscopy. Chi-square tests compared categorical data. Diagnostic accuracy variables (sensitivity/specificity/positive predictive value [PPV]/negative predictive value [NPV]) were calculated for one, two and three FIT (95% CI). Three negative FIT (<10 μg Hb/g of faeces [μg/g]) groups (one, two, three) were compared with positive groups (one or more FIT ≥10 μg/g). CRC and SBD detection rates were compared by strategy.
Results:
A total of 460 patients (mean age: 66.8 years, 233 males and 227 females, 23 CRC, 80 SBD) were included in the study. For one, two and three negative FIT, CRC sensitivity remained static (95.7%); specificity (44.6%, 40.7% and 38.4%) and NPV decreased (99.5%, 99.4% and 99.4%). For SBD, sensitivity increased (78.8%, 83.8% and 86.3%), specificity decreased (47.4%, 43.7% and 41.6%) and NPV increased (91.4%, 92.7% and 93.5%). In one, two and three positive FIT groups, CRC detection was 8.3%,16.1% and 20.9%. CRC mean FIT was 150 μg/g, <6 μg/g for benign pathology.
Conclusions:
One or more negative FIT increases the sensitivity for CRC/SBD. Repeating FIT provides greater differentiation of patients with and without CRC/SBD compared to single FIT but is associated with decreased specificity and PPV. Multiple negative FIT may offer reassurance; however, application of repeating FIT may be restricted given the associated increase in investigations.
Related Concept Videos
Serum Laboratory Studies, Stool Test, Breath Test
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Inflammatory Bowel Disease III: Diagnostic Studies and Management I-Nutritional Therapy
Diagnostic studies
A colonoscopy is the definitive screening test, distinguishing ulcerative colitis from other colon diseases with similar symptoms. During a colonoscopy test, inflamed mucosa with exudate ulcerations can be observed, and biopsies are taken to determine the histologic characteristics of the...

