Related Experiment Video
Updated: Jun 16, 2025

Measurement of Tissue Oxygenation Using Near-Infrared Spectroscopy in Patients Undergoing Hemodialysis
Published on: October 2, 2020
Magnitude and precision of absolute blood volume estimated during hemodialysis
Rammah Abohtyra1,2, Tyrone Vincent3, Daniel Schneditz4
1Department of Electrical Engineering, The University of Texas Permian Basin, Midland, TX, USA.
Background: Management of body fluid volumes and adequate prescription of ultrafiltration (UF) remain key issues in the treatment of chronic kidney disease patients.Objective: This study aims to estimate the magnitude as well as the precision of absolute blood volume () modeled during regular hemodialysis (HD) using standard data available with modern dialysis machines.Methods: The estimation utilizes a two-compartment fluid model and a mathematical optimization technique to predict UF-induced changes in hematocrit measured by available on-line techniques. The method does not rely on a specific hematocrit sensor or a specific UF or volume infusion protocol and uses modeling and prediction tools to quantify the error in estimation.Results: The method was applied to 21 treatments (pre-UF body mass: 65.5713.44 kg, UF-volume: 3.991.14 L) obtained in ten patients (4 female). Pre-HD was 5.40.53 L with an average coefficient of variation of 9.8% (range 1 to 22%). A significant moderate correlation was obtained when was compared to a different method applied to the same data set (r = 0.5). Specific blood volumes remained above the critical level of 65 mL/kg in 17 treatments (80.9%).Conclusion: The method offers the opportunity to detect critical blood volumes during HD and to judge the quality and reliability of that information based on the precision of the estimate.
Background: Management of body fluid volumes and adequate prescription of ultrafiltration (UF) remain key issues in the treatment of chronic kidney disease patients.Objective: This study aims to estimate the magnitude as well as the precision of absolute blood volume () modeled during regular hemodialysis (HD) using standard data available with modern dialysis machines.Methods: The estimation utilizes a two-compartment fluid model and a mathematical optimization technique to predict UF-induced changes in hematocrit measured by available on-line techniques. The method does not rely on a specific hematocrit sensor or a specific UF or volume infusion protocol and uses modeling and prediction tools to quantify the error in estimation.Results: The method was applied to 21 treatments (pre-UF body mass: 65.5713.44 kg, UF-volume: 3.991.14 L) obtained in ten patients (4 female). Pre-HD was 5.40.53 L with an average coefficient of variation of 9.8% (range 1 to 22%). A significant moderate correlation was obtained when was compared to a different method applied to the same data set (r = 0.5). Specific blood volumes remained above the critical level of 65 mL/kg in 17 treatments (80.9%).Conclusion: The method offers the opportunity to detect critical blood volumes during HD and to judge the quality and reliability of that information based on the precision of the estimate.
Related Concept Videos
Errors occurring during blood pressure monitoring
Several factors...
Uncertainty in Measurement: Reading Instruments
Dialysis
Acute kidney injury develops suddenly and can be caused by pre-renal causes (e.g., hypovolemia, shock), intrinsic renal causes (e.g., acute tubular necrosis), or post-renal causes (e.g., urinary obstruction). In contrast, chronic renal failure progresses gradually over time and is often...
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)