Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
Parallel coupling of gas chromatography to mass spectrometry and solid deposition Fourier transform infrared
Carmelo Coppolino1, Emanuela Trovato1, Tania M G Salerno2
1Messina Institute of Technology c/o Department of Chemical, Biological, Pharmaceutical and Environmental Sciences, former Veterinary School, University of Messina, Viale G. Palatucci snc, 98168, Messina, Italy.
Abstract:
The request for novel hyphenated instruments and techniques, capable of affording exhaustive information and results, is a focus continuously watched out. In this context, the present work aimed at the development of an integrated system combining gas chromatographic (GC) separation with mass spectrometry (MS) and (solid deposition) Fourier transform infrared spectroscopy (FTIR) detection. An external transfer line was designed in the lab for the parallel coupling of the two detectors, in such a way to obtain complementary analytical information consisting of an MS spectrum, an IR spectrum and linear retention indices (LRI), within a single analysis. The instrument performance was demonstrated for the analysis of a commercial mixture consisting of 139 hydrocarbons, comprising linear, branched, unsaturated and aromatic compounds. A 100-m poly(dimethylsiloxane) column was employed for the separation, and the outlet flow was split 95:5 between the IR and MS detectors using two uncoated capillaries. The IR spectra were acquired from solid deposits on a zinc selenide disc (-90 °C), over a spot (detector area) of about 0.1 mm2, in the range of 4000-700 cm-1 and at a resolution of 4 cm-1. Final identification of the separated compounds by a library search was achieved by excluding incorrect results, sequentially using a three-filter approach (85% similarity against reference MS and IR library spectra and ±10 LRI unit tolerance). Based on these preliminary results, the GC-MS/sd-FTIR system is a promising tool for the characterization of complex matrix constituents, for which identification is cumbersome, by using only one detection technique.
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Tandem Mass Spectrometry
Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called collision-induced...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Gas Chromatography: Types of Detectors-II