Super-resolution NMR spectroscopy
Luca Wenchel1, Olivia Gampp1, Roland Riek1
1Institute of Molecular Physical Science, ETH Zürich, Vladimir-Prelog-Weg 2, CH-8093 Zürich, Switzerland.
Abstract:
Spectral resolution is one of the limiting factors in nuclear magnetic resonance (NMR) spectroscopy of biological systems where signal overlap often interferes with chemical shift assignment as well as dynamics and structure analysis. This problem can be addressed in part by using higher magnetic field NMR spectrometers operating at up to 1.2 GHz 1H frequency to enhance the resolution proportionally with the field strength, and by deuteration in combination with transverse relaxation-optimized spectroscopy that reduces the transverse relaxation rate and proportionally the resonance linewidth of the peaks yielding higher spectral resolution. As a complement or alternative to these expensive and often insufficient approaches, we present here a generally applicable method to reduce the linewidth of peaks in indirect dimensions of multi-dimensional NMR spectra by increasing the number of scans per time increment exponentially as a function of time in order to compensate, in part, the decay of the signal caused by transverse relaxation. This enables to achieve a user-defined linewidth of the peaks without undue increase of the noise. Optimization by including in the number of scans also a cosine apodization function as well as processing spectra with an exponential-cosine window function in the direct dimension results typically in a resolution enhancement (linewidth reduction) by a factor of 1.5-2 in comparison to a standard measurement with a constant number of scans per time increment. This is comparable to the 2-fold resolution enhancement that can be obtained by going from a 600 MHz 1H frequency NMR spectrometer to a 1.2 GHz instrument, or from 1.2 GHz to a spectrum measured hypothetically at 2.4 GHz 1H frequency. A factor of two resolution enhancement causes thereby a signal to noise loss of a factor of three. The sensitivity gain by dynamic number of scan sampling is thereby ∼20 % over the use of a digital apodization function.
Related Concept Videos
NMR Spectrometers: Resolution and Error Correction
Super-resolution Fluorescence Microscopy
Double Resonance Techniques: Overview
Spin decoupling is usually achieved by...
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are...
2D NMR: Overview of Homonuclear Correlation Techniques
COSY90 is the standard two-dimensional (2D) COSY experiment that...
Two-Dimensional (2D) NMR: Overview
The first step is the preparation period, during which nucleus A is excited with a radiofrequency pulse....