Detection of Architectural Distortion in Prior Mammograms via Analysis of Oriented Patterns
Published on: August 30, 2013
Survey on Current Utilization and Perception of Synthesized Mammography
Kristen Coffey1, Katerina Dodelzon1, Vandana Dialani2
1Department of Radiology, Weill Cornell Medicine, New York, NY, USA.
Objective:
To assess utilization and perceptions of 2D synthesized mammography (SM) for digital breast tomosynthesis (DBT) among practicing U.S. breast radiologists.
Methods:
An IRB-exempt 23-question anonymized survey was developed by the Society of Breast Imaging (SBI) Patient Care and Delivery Committee and emailed to practicing U.S. radiologist SBI members on October 9, 2023. Questions assessed respondents' demographics, current mammographic screening protocol, confidence interpreting SM for mammographic findings, and perceived advantages and disadvantages of SM.
Results:
Response rate was 13.4% (371/2771). Of 371 respondents, 208 were currently screening with DBT/SM (56.1%), 98 with DBT/SM/digital mammography (DM) (26.4%), 61 with DBT/DM (16.4%), and 4 with DM (1.1%). Most respondents felt confident using DBT/SM to evaluate masses (254/319, 79.6%), asymmetries (247/319, 77.4%), and distortions (265/318, 83.3%); however, confidence was mixed for calcifications (agreement 130/320, 40.6%; disagreement 156/320, 48.8%; neutral 34/320, 10.6%). The most frequently cited disadvantage and advantage of SM were reconstruction algorithm false-positive results (199/347, 57.4%) and lower radiation dose (281/346, 81.2%), respectively. Higher confidence and fewer disadvantages were reported by radiologists who had more SM experience, screened with DBT/SM, or exclusively used Hologic vendor (all P <.05).
Conclusion:
For most survey respondents (56.1%), SM has replaced DM in DBT screening. Radiologists currently screening with DBT/SM or with more SM experience reported greater confidence in SM with fewer perceived disadvantages.
More Related Videos
05:04Author Spotlight: Evaluating Clinicians' Adoption of Ultrasound-Guided Vascular Cannulation Through Simulation Training
Published on: August 9, 2024
15:48Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging
Published on: December 15, 2014
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Magnetic Resonance Imaging
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...