Determination of Ca, P, K, Na, and Mg in Australian Retail Pasteurised Milk Using Inductively Coupled Plasma Atomic
Duc Doan Nguyen1,2, Vicky Solah1,2, Suzanne Daubney3
1Food Science and Nutrition Centre for Crop and Food Innovation Food Futures Institute Murdoch University, Murdoch Western Australia 6150, Australia.
Abstract:
A rapid and simple inductively coupled plasma atomic emission spectrometry (ICP OES) method was developed and validated for the determination of macroelements including calcium (Ca), phosphorus (P), potassium (K), sodium (Na), and magnesium (Mg) in Australian retail pasteurised milk. The milk samples were digested using the mixture of 70% HNO3 and 30% H2O2 (2 : 1, v/v) in an open-tube digester block at 120°C for 4 h. The validated ICP OES method showed good linearity for all elements (R 2 > 0.9993). The method limits of quantification (LOQ) for Ca, P, K, Na, and Mg were 19.85, 8.97, 100.8, 41.92, and 11.56 µg·g-1, respectively. Recoveries were in the range of 91.54-116.0%. Repeatability and interday reproducibility expressed as the relative standard deviation (% RSD) was below 5.0%. The contents of macroelements in 6 retail pasteurised milk samples were between 1099.32 and 1348.65 µg·g-1 (Ca), 914.01 and 1091.21 µg·g-1 (P), 1362.76 and 1549.74 µg·g-1 (K), 288.89 and 323.22 µg·g-1 (Na), and 97.62 and 110.57 µg·g-1 (Mg). Principal component analysis (PCA) revealed that retail pasteurised milk samples were distinctly separated into four groups on the first two principal components (PCs). The difference in the macroelement content between milk brands might be affected by milk regions.
Related Concept Videos
Qualitative Analysis
For instance, group IV...
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Atomic Emission Spectroscopy: Lab
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...