Related Experiment Video
Updated: Jun 9, 2026

Ultrasound Imaging-guided Intracardiac Injection to Develop a Mouse Model of Breast Cancer Brain Metastases Followed by Longitudinal MRI
Published on: March 6, 2014
Artificial intelligence-assisted volume isotropic simultaneous interleaved bright- and black-blood examination for
Kazufumi Kikuchi1, Osamu Togao2, Yoshitomo Kikuchi3
1Department of Clinical Radiology, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan. kikuchi.kazufumi.953@m.kyushu-u.ac.jp.
Purpose:
To verify the effectiveness of artificial intelligence-assisted volume isotropic simultaneous interleaved bright-/black-blood examination (AI-VISIBLE) for detecting brain metastases.
Methods:
This retrospective study was approved by our institutional review board and the requirement for written informed consent was waived. Forty patients were included: 20 patients with and without brain metastases each. Seven independent observers (three radiology residents and four neuroradiologists) participated in two reading sessions: in the first, brain metastases were detected using VISIBLE only; in the second, the results of the first session were comprehensively evaluated by adding AI-VISIBLE information. Sensitivity, diagnostic performance, and false positives/case were evaluated. Diagnostic performance was assessed using a figure-of-merit (FOM). Sensitivity and false positives/case were evaluated using McNemar and paired t-tests, respectively.
Results:
The McNemar test revealed a significant difference between VISIBLE with/without AI information (P < 0.0001). Significantly higher sensitivity (94.9 ± 1.7% vs. 88.3 ± 5.1%, P = 0.0028) and FOM (0.983 ± 0.009 vs. 0.972 ± 0.013, P = 0.0063) were achieved using VISIBLE with AI information vs. without. No significant difference was observed in false positives/case with and without AI information (0.23 ± 0.19 vs. 0.18 ± 0.15, P = 0.250). AI-assisted results of radiology residents became comparable to results of neuroradiologists (sensitivity, FOM: 85.9 ± 3.4% vs. 90.0 ± 5.9%, 0.969 ± 0.016 vs. 0.974 ± 0.012 without AI information; 94.8 ± 1.3% vs. 95.0 ± 2.1%, 0.977 ± 0.010 vs. 0.988 ± 0.005 with AI information, respectively).
Conclusion:
AI-VISIBLE improved the sensitivity and performance for diagnosing brain metastases.
Related Concept Videos
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Imaging Studies VII: Vascular Imaging