Real-time fluorescent multiple cross displacement amplification for rapid and sensitive Mycoplasma pneumoniae detection
Related Experiment Video
Updated: Jun 1, 2026

Optimized PCR-based Detection of Mycoplasma
Published on: June 20, 2011
Fei Xiao1, Yu Zhang1, Wenjian Xu2
1Experiment Research Center, Capital Institute of Pediatrics, Beijing, China.
Abstract:
Mycoplasma pneumoniae is a significant pathogen responsible for community-acquired pneumonia, predominantly affecting children and adolescents. Here, we devised a rapid method for M. pneumoniae that combined multiple cross displacement amplification (MCDA) with real-time fluorescence technology. A set of ten primers, which were specifically designed for M. pneumoniae detection, were employed in a real-time fluorescence MCDA reaction. Of these, one primer incorporated a restriction endonuclease recognition sequence, a fluorophore, and a quencher, facilitating real-time fluorescence detection. The real-time (RT)-MCDA reactions were monitored in a simple real-time fluorescence instrument and conducted under optimised conditions (64°C for 40 min). The detection limit of the M. pneumoniae RT-MCDA assay for genomic DNA extracted from M. pneumoniae culture was down to 43 fg/µl. This assay accurately identified M. pneumoniae strains without cross-reacting with other bacteria. To validate its practical application, we tested the M. pneumoniae RT-MCDA assay using genomic DNA extracted from clinical samples. The assay's detection capability proved comparable with real-time PCR, MCDA-based biosensor detection, and visual inspection under blue light. The entire process, including rapid DNA extraction and real-time MCDA detection, was completed within 1 h. Overall, the M. pneumoniae RT-MCDA assay reported here is a simple and effective diagnostic tool for rapid M. pneumoniae detection, which holds significant potential for point-of-care testing and in resource-limited regions.
Insights
A new rapid diagnostic method for Mycoplasma pneumoniae (M. pneumoniae) combines multiple cross displacement amplification (MCDA) with real-time fluorescence. This efficient assay detects M. pneumoniae DNA in under an hour, showing promise for point-of-care testing.
Area of Science:
- Microbiology
- Molecular Diagnostics
- Biotechnology
Background:
- Mycoplasma pneumoniae is a primary cause of community-acquired pneumonia, particularly in pediatric populations.
- Accurate and rapid detection of M. pneumoniae is crucial for timely treatment and infection control.
Purpose of the Study:
- To develop a rapid, sensitive, and specific diagnostic assay for Mycoplasma pneumoniae.
- To combine multiple cross displacement amplification (MCDA) with real-time fluorescence for enhanced detection.
Main Methods:
- Designed a set of ten specific primers for M. pneumoniae detection.
- Utilized a fluorophore- and quencher-labeled primer for real-time fluorescence monitoring.
- Optimized real-time (RT)-MCDA conditions at 64°C for 40 minutes using a simple fluorescence instrument.
Main Results:
- Achieved a detection limit as low as 43 fg/µl for M. pneumoniae genomic DNA.
- Demonstrated high specificity, with no cross-reactivity with other bacterial species.
- Clinical sample testing showed comparable performance to real-time PCR and biosensor detection.
Conclusions:
- The developed RT-MCDA assay provides a simple, rapid, and effective diagnostic tool for M. pneumoniae.
- The assay's speed (under 1 hour) and sensitivity make it suitable for point-of-care applications.
- This method holds significant potential for use in resource-limited settings for rapid pathogen detection.