Related Experiment Video
Updated: May 4, 2026

2-Methacryloyloxyethyl Phosphorylcholine Polymer Treatment of Complete Dentures to Inhibit Denture Plaque Deposition
Published on: December 26, 2016
Effects of two dentifrices on the surface properties and staining susceptibility of polymer-based materials
Rua Babaier1, Abdulaziz Alhotan2, Julfikar Haider3,4
1Prosthetic Dental Sciences, College of Dentistry, King Saud University, Riyadh, Saudi Arabia.
Purpose:
This study examined the effect of whitening and abrasive regular dentifrices on the surface characteristics and stain susceptibility of polymer-based CAD-CAM blocks subjected to artificial toothbrushing abrasion (TB).
Materials And Methods:
Two resin composite blocks [CeraSmart (CS) and Grandio Blocs (GB)], one polymer-infiltrated ceramic [Vita Enamic (VE)], and one direct resin composite [GrandioSO (RC)] were used to produce 60 specimens. The baseline mass, gloss, roughness, Vickers hardness (Hv), and color were measured after 7 days of water storage. The specimens were then separated into three TB treatment groups (n = 5): water control (C), regular daily dentifrice (R), and whitening dentifrice (W). Measurements were repeated post-TB (20,000 cycles). All specimens were immersed in coffee, and the CIE ΔE00 was measured after 1, 7, and 14 days. Two-way, one-way ANOVA, and Tukey's post hoc tests were performed to determine any significant differences between the materials and TB groups. To determine the stain resistance, repeated measures of ANOVA, one-way ANOVA, and Tukey's post hoc tests were used (α = 0.05).
Results:
The R and W mass changes were minimal (-3.77 to 3.16 g%). W reduced the gloss of all the materials by 12.6%-65%. All materials in W were slightly rougher (Ra, 0.107-0.144 μm) than those in R (Ra, 0.049-0.072 μm). The ΔE00 ranged from 0.6 to 1.6 in W and 0.4 to 1.4 in R. VE was the hardest material at baseline (Hv = 362), whereas brushing and staining lowered Hv in all TB groups (282.8-300.6). After brushing in W, VE, and RC were more susceptible to coffee stains than were CS and GB.
Conclusions:
The whitening dentifrice roughened CAD-CAM specimens, reducing gloss, yet lightened some materials. Polymer-infiltrated ceramic and direct resin composite specimens brushed with abrasive regular or whitening dentifrice resulted in more intense staining than the CAD-CAM resin composites.
Related Concept Videos
Aryldiazonium Salts to Azo Dyes: Diazo Coupling
Physical Properties of Carboxylic Acid Derivatives
Among the carboxylic acid derivatives, the boiling points of acid chlorides and esters are very similar and are the lowest in the series. Acid anhydrides have slightly higher boiling...
Physical Properties of Carboxylic Acids
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Complexometric Titration: Ligands
Mortar Properties