Fall into the pseudo-decoupling trap: Type identification, trend characterization and solution path of carbon

Tie Wei1, Zhicheng Duan2, Pin Xie2

  • 1School of Business, Guangxi University, Nanning, 530004, China; Guangxi Development Research Strategy Institute, Nanning, 530004, China.

Related Concept Videos

Social Traps01:41

Social Traps

Social traps are negative situations where people get caught in a direction or relationship that later proves to be unpleasant, with no easy way to back out of or avoid. The concept was orignally introduced by John Platt who applied psychology to Garrett Hardin's "Tragedy of the Commons", where in New England herd owners could let their cattle graze in the common ground. This situation seems like a good idea, but an individual could have an advantage. If they owned more cows, the larger...
¹³C NMR: ¹H–¹³C Decoupling01:04

¹³C NMR: ¹H–¹³C Decoupling

The probability of having two carbon-13 atoms next to each other is negligible because of the low natural abundance of carbon-13. Consequently, peak splitting due to carbon-carbon spin-spin coupling is not observed in spectra. However, protons up to three sigma bonds away split the carbon signal according to the n+1 rule, resulting in complicated spectra.
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
Double Resonance Techniques: Overview01:12

Double Resonance Techniques: Overview

Double resonance techniques in Nuclear Magnetic Resonance (NMR) spectroscopy involve the simultaneous application of two different frequencies or radiofrequency pulses to manipulate and observe two distinct nuclear spins. One important application of double resonance is spin decoupling, which selectively suppresses coupling with one type of nucleus while observing the NMR signal from another nucleus, simplifying the spectrum and enhancing resolution.
Spin decoupling is usually achieved by...
Parallel RLC Circuits01:14

Parallel RLC Circuits

Street lamps equipped with RLC surge protectors are an excellent example of applying circuit analysis in practical scenarios. These surge protectors safeguard the lamp's components against sudden voltage spikes.
A simplified parallel RLC circuit model with a DC input source generating a step response is employed in this context. When the switch is turned on, Kirchhoff's current law is applied, leading to a second-order differential equation.
Power Factor Correction01:20

Power Factor Correction

The power transmission to a factory involves the transfer of apparent power, a combination of active and reactive power. The power factor measures how effectively electrical power is converted into useful work output. The ratio of the real power (KW) that does the work to the apparent power (KVA) supplied to the circuit.
Fast Decoupled and DC Powerflow01:24

Fast Decoupled and DC Powerflow

The fast decoupled power flow method addresses contingencies in power system operations, such as generator outages or transmission line failures. This method provides quick power flow solutions, essential for real-time system adjustments. Fast decoupled power flow algorithms simplify the Jacobian matrix by neglecting certain elements, leading to two sets of decoupled equations: