Profiling Volatile Compounds in Blackcurrant Fruit using Headspace Solid-Phase Microextraction Coupled to Gas Chromatography-Mass Spectrometry
Published on: June 9, 2021
[A headspace injection double-column dual-detector gas chromatography system for the analysis of 12 volatile
Qiong-Ying Zheng1,2, Yu-Jie Zhi3, Wenjia Duan2
1College of Forensic Medicine, Shanxi Medical University, Jinzhong 030600, China.
Abstract:
Based on the technical methods of GB/T 42430-2023 and GA/T 204-2019, this study established an analytical method for headspace injection double-column dual-detector (hydrogen flame ion detector) gas chromatography for the simultaneous analysis of at least 12 volatile compounds, including ethanol, in human blood using two different equipment platforms and chromatographic columns. A 100 μL blood or urine sample and a 0.04 g/L tert-butanol working solution prepared as an internal standard are introduced into the headspace sample bottle and then sealed, mixed, and placed on the headspace sampler rack. Using different equipment platforms and columns, methodological parameters such as the limit of detection (LOD), limit of quantification (LOQ), precision, and accuracy of the method were systematically evaluated. The chromatographic separation of acetone, alcohols and benzenes using the established method was satisfactory. The linear ranges, linear correlation coefficients (r), and LODs of acetone and six alcohols, including ethanol, were 0.10-3.00 g/L, >0.997, and 0.05 g/L, respectively. The LOQs were 0.10 g/L for all other compounds, excluding n-propanol (0.005 g/L). Additionally, the linear ranges, r values, LODs, and LOQs of benzene and four benzene derivatives were 0.05-50 mg/L, >0.995, 0.02 mg/L, and 0.05 mg/L, respectively (Column J&W DB-BAC1 UI and Column Rtx-BAC-PLUS 2). The average recoveries of compounds on J&W DB-BAC1 UI and Rtx-BAC-PLUS 2 columns ranged from 92.2% to 111.6%, and the relative standard deviations (RSDs, n=6) ranged from 0.4% to 7.4%. The LOD, LOQ, precision, accuracy, and linearity of the established method met the requirements of relevant standards, and no significant differences arose between the methodological parameters of the two platforms. CNAS-GL006 (2019) and JJF 1059.1-2012 were used as guides to evaluate the uncertainty of ethanol on two different sets of equipment platforms and chromatographic columns. The ethanol uncertainty was mainly derived from the calibration curve; however, the confidence probability was 95% (k=2). According to the analysis of the verification samples and real samples, the established method is suitable for the high-precision quantitative analysis of acetone and six alcohols and five benzene derivatives in human blood and other body fluids. It can be used in practical scenarios such as judicial identification and the detection of poisons.
More Related Videos
Related Concept Videos
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Types of Detectors-II
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...