Related Experiment Video
Updated: Jun 14, 2025

Hydrogel Nanoparticle Harvesting of Plasma or Urine for Detecting Low Abundance Proteins
Published on: August 7, 2014
Diagnostic Performance of Serum Leucine-Rich Alpha-2-Glycoprotein 1 in Pediatric Acute Appendicitis: A Prospective
Javier Arredondo Montero1, Raquel Ros Briones2, Amaya Fernández-Celis3
1Pediatric Surgery Department, Complejo Asistencial Universitario de León, 24008 León, Spain.
Abstract:
Introduction: Leucine-rich alpha-2-glycoprotein 1(LRG-1) is a human protein that has shown potential usefulness as a biomarker for diagnosing pediatric acute appendicitis (PAA). This study aims to validate the diagnostic performance of serum LRG-1 in PAA. Material and Methods: This work is a subgroup analysis from BIDIAP (BIomarkers for DIagnosing Appendicitis in Pediatrics), a prospective single-center observational cohort, to validate serum LRG-1 as a diagnostic tool in PAA. This analysis included 200 patients, divided into three groups: (1) healthy patients undergoing major outpatient surgery (n = 56), (2) patients with non-surgical abdominal pain (n = 52), and (3) patients with a confirmed diagnosis of PAA (n = 92). Patients in group 3 were divided into complicated and uncomplicated PAA. In all patients, a serum sample was obtained during recruitment, and LRG-1 concentration was determined by Enzyme-Linked ImmunoSorbent Assay (ELISA). Comparative statistical analyses were performed using the Mann-Whitney U, Kruskal-Wallis, and Fisher's exact tests. The area under the receiver operating characteristic curves (AUC) was calculated for all pertinent analyses. Results: Serum LRG-1 values, expressed as median (interquartile range) were 23,145 (18,246-27,453) ng/mL in group 1, 27,655 (21,151-38,795) ng/mL in group 2 and 40,409 (32,631-53,655) ng/mL in group 3 (p < 0.0001). Concerning the type of appendicitis, the serum LRG-1 values obtained were 38,686 (31,804-48,816) ng/mL in the uncomplicated PAA group and 51,857 (34,013-64,202) ng/mL in the complicated PAA group (p = 0.02). The area under the curve (AUC) obtained (group 2 vs. 3) was 0.75 (95% CI 0.67-0.84). For the discrimination between complicated and uncomplicated PAA, the AUC obtained was 0.66 (95% CI 0.52-0.79). Conclusions: This work establishes normative health ranges for serum LRG-1 values in the pediatric population and shows that serum LRG-1 could be a potentially helpful tool for diagnosing PAA in the future. Future prospective multicenter studies, with the parallel evaluation of urinary and salivary LRG-1, are necessary to assess the implementability of this molecule in actual clinical practice.
More Related Videos
06:50A High-Throughput Electrochemiluminescence 7-Plex Assay Simultaneously Screening for Type 1 Diabetes and Multiple Autoimmune Diseases
Published on: May 29, 2020
05:45Diagnosis of Hirschsprung's Disease by Immunostaining Rectal Suction Biopsies for Calretinin, S100 Protein and Protein Gene Product 9.5
Published on: April 26, 2019
Related Concept Videos
Appendicitis-II: Diagnostic Studies and Management
Diagnosing Appendicitis
It requires a multifaceted approach, starting with a detailed physical examination to pinpoint the location and nature of the pain and identify any associated symptoms. Laboratory tests play a crucial role. A complete Blood Count (CBC) typically reveals leukocytosis (an increased number of...
Appendicitis-I: Introduction
Etiology: Appendicitis can arise from various causes, primarily rooted in the obstruction of the appendix lumen. Factors contributing to this obstruction include fecal accumulation, lymphoid hyperplasia and, in...
Peptic Ulcer Disease III: Clinical Manifestations and Diagnostic Studies
Few clinical manifestations differentiate gastric ulcers from duodenal ulcers. Distinctions in the location, timing, and pain relief are crucial for healthcare providers in differentiating between gastric and duodenal ulcers during clinical assessments.