A New Semi-Quantum Two-Way Authentication Protocol between Control Centers and Neighborhood Gateways in Smart Grids

Qiandong Zhang1, Kejia Zhang1,2, Kunchi Hou1

  • 1School of Mathematical Science, Heilongjiang University, Harbin 150080, China.

PubMed

Related Concept Videos

Pilot and Numeric Relaying01:21

Pilot and Numeric Relaying

Pilot relaying is a type of differential protection used in power systems. It compares electrical quantities at the terminals of equipment via a communication channel instead of direct relay interconnection. This method is essential for transmission lines where the terminals are far apart, typically up to 80 km for lines with 69 to 115 kV ratings. Four types of communication channels are used for pilot relaying:
83
Power System Three-Phase Short Circuits01:21

Power System Three-Phase Short Circuits

Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
78
Three-Phase Voltages01:30

Three-Phase Voltages

A three-phase generator produces three voltages that are equal in magnitude but have a phase difference of 120 degrees. This identical magnitude and equal phase separated voltages are known as the balanced voltages and help to minimize power loss while ensuring a steady delivery of energy to connected loads. As voltage sources in a three-phase system can be configured in a wye or a delta formation, the loads connected to these systems can also be arranged in either configuration. This...
221
Generation of Three-Phase Voltage01:21

Generation of Three-Phase Voltage

A three-phase AC generator has a rotor with a rotating magnet placed within the stator mounted with the stationary three-phase winding to generate three-phase voltages via mutual induction. These windings are evenly distributed around the inner circumference of the stator and are arranged 120 electrical degrees apart. Three-phase stator windings consist of three separate coils or groups of coils, known as phases, each connected in Y (star) configuration or Delta configuration.
As the rotor...
365
Three-Phase Circuits01:22

Three-Phase Circuits

AC power distribution systems have three categories: single-phase, two-phase, and three-phase systems. The single-phase circuit, common in residential settings, typically employs a two-wire system connecting a single AC source to various loads. These circuits support standard household appliances operating at 120 volts (V) and 240 V, such as lamps, televisions, and microwaves. The first generators, Niagara Falls hydro plant installed in 1895, were two-phase and designed by Nikola Tesla. The...
394
Secondary Distribution01:25

Secondary Distribution

Secondary distribution systems provide electrical energy at the utilization voltage levels from distribution transformers to customer meters. Typical secondary voltages in the United States include 120/240 V for residential use, 208Y/120 V for residential and commercial use, and 480Y/277 V for industrial and high-rise commercial use.
In residential areas, 120/240 V single-phase, three-wire service is commonly used for lighting, outlets, and large appliances. Urban areas with high-density loads...
82