Correction: Zhang et al. A New Semi-Quantum Two-Way Authentication Protocol between Control Centers and Neighborhood Gateways in Smart Grids. Entropy 2024, 26, 644
Related Experiment Video
Updated: May 11, 2026

10:36
Electric-field Control of Electronic States in WS2 Nanodevices by Electrolyte Gating
Published on: April 12, 2018
11.4K
Qiandong Zhang1, Kejia Zhang1,2, Kunchi Hou1
1School of Mathematical Science, Heilongjiang University, Harbin 150080, China.
Entropy (Basel, Switzerland)
|October 25, 2024
Abstract:
In the published publication [...].
Related Concept Videos
Free Energy Changes for Nonstandard States
The free energy change for a process taking place with reactants and products present under nonstandard conditions (pressures other than 1 bar; concentrations other than 1 M) is related to the standard free energy change according to this equation:
The Z-Scheme of Electron Transport in Photosynthesis
The light reactions of photosynthesis assume a linear flow of electrons from water to NADP+. During this process, light energy drives the splitting of water molecules to produce oxygen. However, oxidation of water molecules is a thermodynamically unfavorable reaction and requires a strong oxidizing agent. This is accomplished by the first product of light reactions: oxidized P680 (or P680+), the most powerful oxidizing agent known in biology. The oxidized P680 that acquires an electron from the...
Electrochemical Systems
Electrochemical systems provide a fascinating insight into the dynamic interplay of charged species within various phases. One notable example is the interaction between a membrane permeable to K⁺ ions but not to Cl⁻ ions, separating an aqueous KCl solution from pure water. As K⁺ ions diffuse through the membrane, they generate net charges on each phase, leading to a potential difference between them.Similarly, when a piece of Zn is immersed in an aqueous ZnSO₄ solution, the Zn metal, composed...
Zones of Protection
In power systems, the entire setup is divided into protective zones to isolate faults and protect the rest of the network. These zones include generators, transformers, buses, transmission lines, distribution lines, and motors. Each zone can be visualized as a separate room in a house, with each room protected by its own circuit breaker.
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
Pilot and Numeric Relaying
Pilot relaying is a type of differential protection used in power systems. It compares electrical quantities at the terminals of equipment via a communication channel instead of direct relay interconnection. This method is essential for transmission lines where the terminals are far apart, typically up to 80 km for lines with 69 to 115 kV ratings. Four types of communication channels are used for pilot relaying: