Investigation of X-rays Beams Uniformity in Radiotherapeutic Tumor Treatment Procedure Using LuAG:Ce Crystal
Sandra Witkiewicz-Łukaszek1, Janusz Winiecki2,3, Paulina Michalska2
1Faculty of Physics, Kazimierz Wielki University in Bydgoszcz, Powstańców Wielkopolskich Street 2, 85-090 Bydgoszcz, Poland.
Cerium-doped Lutetium Aluminum Garnet (LuAG:Ce) crystal detectors show promise for radiotherapy. These detectors offer uniform properties, high thermoluminescence yield, and stability for precise radiation dosimetry.
Area of Science:
- Materials Science
- Medical Physics
- Radiation Detection
Background:
- Radiotherapy requires precise dosimetry for effective cancer treatment.
- Traditional dosimeters face challenges in accuracy and stability under high radiation doses.
- Advanced materials are needed for improved radiation detection in clinical settings.
Purpose of the Study:
- To investigate the potential of Ce3+-doped Lu3Al5O12 garnet (LuAG:Ce) crystals as detectors for radiotherapy.
- To evaluate the dosimetric properties of LuAG:Ce detectors for clinical X-ray beams and gamma sources.
- To assess the uniformity, stability, and performance of LuAG:Ce detectors in a clinical environment.
Main Methods:
- Fabrication and characterization of Ce3+-doped Lu3Al5O12 garnet (LuAG:Ce) single crystal detectors.
- Measurement of thermoluminescence (TL) properties, including light yield and glow peak temperatures.
- Evaluation of radiation stability and uniformity of LuAG:Ce detectors using clinical accelerators (6 MV, 15 MV) and a 60Co gamma source.
Main Results:
- LuAG:Ce detectors exhibit excellent structural and optical uniformity, high TL light yield, and optimal glow peak temperatures (245-295 °C).
- The detectors demonstrate high radiation stability, crucial for repeated use in radiotherapy.
- LuAG:Ce detectors accurately registered dose and energy spectra for 6 MV and 15 MV X-ray beams and 60Co gamma rays (1.17, 1.33 MeV).
Conclusions:
- Ce3+-doped Lu3Al5O12 garnet (LuAG:Ce) crystals are highly promising materials for radiotherapy dosimetry.
- LuAG:Ce detectors offer superior performance characteristics compared to conventional dosimeters.
- These detectors can be reliably used for precise radiation measurements in clinical environments.