Related Concept Videos

Positron Emission Tomography01:29

Positron Emission Tomography

4.1K
Positron emission tomography (PET) is a medical imaging technique involving radiopharmaceuticals — substances that emit short-lived radiation. Although the first PET scanner was introduced in 1961, it took 15 more years before radiopharmaceuticals were combined with the technique and revolutionized its potential.
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
4.1K
Scanning Electron Microscopy01:07

Scanning Electron Microscopy

4.2K
A scanning electron microscope (SEM) is used to study the surface features of a sample by using an electron beam that scans the sample surface in a two-dimensional manner. Typically, areas between ~1 centimeter to 5 micrometers in width can be imaged. SEM can be used to image bacteria, viruses, tissues as well as larger samples like insects. Conventional SEM gives a magnification ranging from 20X to 30,000X and spatial resolution of 50 to 100 nanometers.
Fundamental Principles
Accelerated...
4.2K
Imaging Studies II: Positron Emission Tomography and Scintigraphy01:25

Imaging Studies II: Positron Emission Tomography and Scintigraphy

95
Positron Emission Tomography (PET) is a medical imaging technique that provides crucial insights into the body's physiological functions at a molecular level. It is an indispensable resource for diagnosing, staging, and monitoring various illnesses, notably cancer, neurological disorders, and cardiovascular conditions.
Fundamental Principles of PET
95

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Influence of Rhenium Content on Vacancy-Type Defect Distribution in Mo-Re Alloys Under Room-Temperature Irradiation.

Materials (Basel, Switzerland)·2026
Same author

AI-guided design of efficient perovskite solar cells operationally stable at 100°C.

Science (New York, N.Y.)·2026
Same author

Construction of Two Electroactive (3,24)-Connected <i>rht</i> Metal-Organic Frameworks: Anion-Dependent Charge/Electron and Energy Transfer.

Inorganic chemistry·2026
Same author

Determination of Cell Viability-Acridine Orange/Propidium Iodide (AO/PI) Staining Method.

Cell proliferation·2026
Same author

An integrated immunopathological model of syphilis serofast: a systematic review and meta-analysis.

Frontiers in immunology·2026
Same author

Steric Interaction-Engineered Free Volume Network in Polyamide Nanofiltration Membranes for Ultrafast Water Purification.

Environmental science & technology·2026

Related Experiment Video

Updated: Jun 14, 2025

A Basic Positron Emission Tomography System Constructed to Locate a Radioactive Source in a Bi-dimensional Space
14:19

A Basic Positron Emission Tomography System Constructed to Locate a Radioactive Source in a Bi-dimensional Space

Published on: February 1, 2016

8.5K

Single-pixel positron beam diagnosis via compressive sampling.

Jia-Yi Xu1,2, Peng Kuang2,3, Xing-Zhong Cao2,4,3

  • 1School of Science, China University of Geosciences (Beijing), Beijing 100083, China.

The Review of Scientific Instruments
|August 30, 2024
PubMed
Summary

A new method for diagnosing positron beams uses compressive sampling to reconstruct particle beam morphology. This technique achieves high resolution and faster sampling rates than traditional pixel scanning methods.

More Related Videos

Using Synchrotron Radiation Microtomography to Investigate Multi-scale Three-dimensional Microelectronic Packages
08:46

Using Synchrotron Radiation Microtomography to Investigate Multi-scale Three-dimensional Microelectronic Packages

Published on: April 13, 2016

10.1K
Visualization of Low-Level Gamma Radiation Sources Using a Low-Cost, High-Sensitivity, Omnidirectional Compton Camera
06:28

Visualization of Low-Level Gamma Radiation Sources Using a Low-Cost, High-Sensitivity, Omnidirectional Compton Camera

Published on: January 30, 2020

12.5K

Related Experiment Videos

Last Updated: Jun 14, 2025

A Basic Positron Emission Tomography System Constructed to Locate a Radioactive Source in a Bi-dimensional Space
14:19

A Basic Positron Emission Tomography System Constructed to Locate a Radioactive Source in a Bi-dimensional Space

Published on: February 1, 2016

8.5K
Using Synchrotron Radiation Microtomography to Investigate Multi-scale Three-dimensional Microelectronic Packages
08:46

Using Synchrotron Radiation Microtomography to Investigate Multi-scale Three-dimensional Microelectronic Packages

Published on: April 13, 2016

10.1K
Visualization of Low-Level Gamma Radiation Sources Using a Low-Cost, High-Sensitivity, Omnidirectional Compton Camera
06:28

Visualization of Low-Level Gamma Radiation Sources Using a Low-Cost, High-Sensitivity, Omnidirectional Compton Camera

Published on: January 30, 2020

12.5K

Area of Science:

  • Physics
  • Particle Accelerators
  • Beam Diagnostics

Background:

  • Particle beam morphology is vital for diagnosing low-energy, low-brightness beams.
  • Conventional positron beam diagnosis methods face limitations due to detector pixel resolution.

Purpose of the Study:

  • To introduce a novel slow positron diagnosis method utilizing compressive sampling.
  • To overcome the physical constraints of traditional pixel scanning techniques.

Main Methods:

  • Implemented a compressive sampling approach for slow positron beam diagnosis.
  • Utilized a 100 × 100 pixel-sized mask for reconstruction.
  • Compared performance against traditional pixel scanning.

Main Results:

  • Successfully reconstructed positron beam morphology with compressive sampling.
  • Achieved a peak signal-to-noise ratio of approximately 40 dB.
  • Demonstrated effective reconstruction at half the sampling rate of pixel scanning.

Conclusions:

  • Compressive sampling offers a promising approach for ultra-high resolution and fast positron beam diagnosis.
  • The novel method overcomes limitations of conventional pixel scanning.
  • This technique enhances the capabilities of particle beam analysis.