Development and Evaluation of 3D-Printed Cardiovascular Phantoms for Interventional Planning and Training
Published on: January 18, 2021
Assessing aortic motion with automated 3D cine balanced steady state free precession cardiovascular magnetic
Renske Merton1, Daan Bosshardt1, Gustav J Strijkers2
1Amsterdam UMC location University of Amsterdam, Radiology and Nuclear Medicine, Meibergdreef 9, Amsterdam, the Netherlands; Amsterdam Cardiovascular Sciences, Atherosclerosis and Ischemic Syndromes, Amsterdam, the Netherlands.
Purpose:
To apply a free-running three-dimensional (3D) cine balanced steady state free precession (bSSFP) cardiovascular magnetic resonance (CMR) framework in combination with artificial intelligence (AI) segmentations to quantify time-resolved aortic displacement, diameter and diameter change.
Methods:
In this prospective study, we implemented a free-running 3D cine bSSFP sequence with scan time of approximately 4 min facilitated by pseudo-spiral Cartesian undersampling and compressed-sensing reconstruction. Automated segmentation of the aorta in all cardiac timeframes was applied through the use of nnU-Net. Dynamic 3D motion maps were created for three repeated scans per volunteer, leading to the detailed quantification of aortic motion, as well as the measurement and change in diameter of the ascending aorta.
Results:
A total of 14 adult healthy volunteers (median age, 28 years (interquartile range [IQR]: 26.0-31.3), 6 females) were included. Automated segmentation compared to manual segmentation of the aorta test set showed a Dice score of 0.93 ± 0.02. The median (IQR) over all volunteers for the largest maximum and mean ascending aorta (AAo) displacement in the first scan was 13.0 (4.4) mm and 5.6 (2.4) mm, respectively. Peak mean diameter in the AAo was 25.9 (2.2) mm and peak mean diameter change was 1.4 (0.5) mm. The maximum individual variability over the three repeated scans of maximum and mean AAo displacement was 3.9 (1.6) mm and 2.2 (0.8) mm, respectively. The maximum individual variability of mean diameter and diameter change were 1.2 (0.5) mm and 0.9 (0.4) mm.
Conclusion:
A free-running 3D cine bSSFP CMR scan with a scan time of four minutes combined with an automated nnU-net segmentation consistently captured the aorta's cardiac motion-related 4D displacement, diameter, and diameter change.
More Related Videos
11:13Quantification of Mouse Heart Left Ventricular Function, Myocardial Strain, and Hemodynamic Forces by Cardiovascular Magnetic Resonance Imaging
Published on: May 24, 2021
08:10Estimating Bilateral Atrial Function by Cardiovascular Magnetic Resonance Feature Tracking in Patients with Paroxysmal Atrial Fibrillation
Published on: July 20, 2022
Related Concept Videos
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT