Multi-Organizational Insights Into Radiological Safety Standards in High-Dose Rate Brachytherapy
Anurag Luharia1, Shweta B Dahake1, Ashish Uke2
1Medical Physics, Jawaharlal Nehru Medical College, Datta Meghe Institute of Higher Education and Research, Wardha, IND.
Abstract:
The review provides an extensive study of regulations and recommendations set forth by organizations worldwide in the domain of high-dose rate (HDR) brachytherapy for the prevention and mitigation of radiation hazards. The relevant reports and publications by the International Commission on Radiological Protection (ICRP), International Atomic Energy Agency (IAEA), American Association of Physicists in Medicine (AAPM), United States (US) Nuclear Regulatory Commission (NRC), and Atomic Energy Regulatory Board (AERB) were accessed, and necessary information was compiled to clarify and understand concepts, similarities, and differences in safety standards concerning to the topic. The regulations and guidance are categorized under three major components of safety, namely layout, equipment, and source. Layout category accesses structure, design, layout, and survey. The equipment category summarizes the requirements of equipment, installation, commissioning, quality assurance (QA) and performance, safety precautions and preparedness, safety procedures, and instructions. The source category includes requirements for sealed source possession and use, calibration, categorization, certification, licensing, QA tests, and security. IAEA gives inclusive guidance on radiation protection and regulatory requirements, forming the basis of reference for other organizations worldwide. AERB regulates the radiation facilities in India; therefore, most set-ups follow their safety standards and instructions.
Related Concept Videos
Biological Effects of Radiation
Radiological Investigation I: X-ray and CT
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...