Dacryocystitis Secondary to Orbital Mesh Implant Impingement: A Rare Etiology
Arulvignesh M1, Lakshmi Rathan A C1, Vivek Narayanan1
1Department of Oral and Maxillofacial Surgery, SRM Kattankulathur Dental College and Hospital, SRM Institute of Science and Technology (SRMIST), Chengalpattu, IND.
Abstract:
A 22-year-old male patient reported swelling in relation to the right eye and developed recurrent purulent discharge and epiphora following a reconstructive traumatic orbital floor fracture repair two years ago. Radiographic investigation and surgical exploration reveal obstruction of the lacrimal apparatus at the lacrimal sac level due to over-extension/migration of the orbital floor mesh. The migration of the mesh was probably due to the extension of the mesh medially into the paranasal region.