Evaluation of the biomechanics of Aramany class I obturators of different designs using numerical and experimental
Mohammed A Mousa1, Adam Husein2, Mohamed I El-Anwar3
1Lecturer, Prosthetic Dental Sciences, College of Dentistry, Jouf University, Sakaka, Saudi Arabia; and Researcher, Prosthodontic Unit, School of Dental Sciences, Universiti Sains Malaysia, Kubang Kerian, Malaysia.
Statement Of Problem:
Evidence regarding stress evaluations of removable obturators with Aramany class I defects is lacking. Whether the stress distribution on Aramany class I prostheses can be improved by modifying the currently used designs is also unclear.
Purpose:
The purpose of part II of this study was to evaluate the stress distribution in different designs of Aramany class I obturators using finite element analysis (FEA) and photoelastic stress analysis.
Material And Methods:
Four finite element and 8 photoelastic models, including 2 acrylic resin base obturators retained with 2 Adams clasps, 2 linear, 2 tripodal, and 2 fully tripodal design obturators, were used in this study. The frameworks were fabricated on the casts obtained from a modified printed model. Vertical and oblique loads were applied on 2 points (anterior and posterior) of the models. The quantitative measurement was done by measuring the fringe orders and von Mises values to compare the influences of occlusal forces on the obturator components and their supporting structures. The qualitative evaluation was done by visual color mapping to identify the stress concentration.
Results:
In the photoelastic analysis, the anterior abutments of the tripodal showed the highest stress, followed by the fully tripodal obturators, while, in FEA, the anterior abutments of the linear design received the most in both vertical and oblique load. The central incisor received the most stress in photoelastic (3 or more fringe orders) and FEA (687.3 and 150.1 MPa for vertical and oblique loads, respectively), followed by the lateral incisors. Upon posterior loading, the base of the defect of the linear design demonstrated the most stress in photoelastic (3 or more fringes) and FEA (94.3 and 130.5 MPa for vertical and oblique loads, respectively). The acrylic resin base obturator retained with Adams clasps demonstrated the lowest stress distribution in abutments and their supporting bone upon anterior and posterior loads.
Conclusions:
Upon vertical and oblique load application, the fully tripodal design was comparable with the tripodal in terms of stress distribution. Both designs were better than the linear in response to the same loading. The stress was concentrated at the anterior palatal part of the obturator, the base of the defect, and the junction of the metal and acrylic resin part of the prostheses upon anterior and posterior loading, respectively.
More Related Videos
11:28A Coupled Experiment-finite Element Modeling Methodology for Assessing High Strain Rate Mechanical Response of Soft Biomaterials
Published on: May 18, 2015
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
Related Concept Videos
Applications of Stress
The...
Stress Concentrations in Circular Shafts
Transformation of Plane Stress
Stress: General Loading Conditions
The shearing force, possessing potential directionality within the plane of the section, is simplified into two component forces running parallel to the x and y axes....
Residual Stresses in Circular Shafts
Stress on an Oblique Plane