Related Experiment Video
Updated: Jun 14, 2025

Three-dimensional Particle Tracking Velocimetry for Turbulence Applications: Case of a Jet Flow
Published on: February 27, 2016
Evaluation of the impact of filter types and parameters upon the accuracy of phase-based optical flow method with a
Zhaoxin Peng1,2, Xian Wang1,2, Zhiliang Wang1,2
1School of Mechanical Engineering, Hunan University of Science and Technology, Xiangtan, China.
Abstract:
Complex steerable pyramid (CSP) performs well when applied to magnify subtle motions of structures for observing the dynamic characteristics of facilities. However, the impact of the types and parameters of CSP filters upon the performance of phase-based optical flow (PBOF) in measuring motion parameters has not been systematically studied. The purpose of this study is to comprehensively evaluate the impact of different CSP filter types (Octave, HalfOctave, SmoothHalfOctave, and QuarterOctave) and parameters on the performance of PBOF in measuring motion parameters. Firstly, by measuring simulated translational motion, the influence of the CSP's down-sampling rates on the displacement measurement accuracy of PBOF is analyzed to determine appropriate settings. Subsequently, the effective displacement measurement interval and accuracy of PBOF using the CSP are studied through simulated and experimental translational motion measurements. Further, the vibration parameter's accuracy is analyzed through simulated periodic vibration measurements. Finally, the characteristics of PBOF using the four kinds of CSP and practical considerations are discussed. Simulation and experimental results demonstrate that when using middle-level filters within the effective level range of HalfOctave, PBOF achieves the best overall displacement measurement performance. Additionally, this method can easily integrate with signal processing techniques in analyzing structural dynamic characteristics under field conditions.
Related Concept Videos
Phase-lead and Phase-lag Controllers
Time and frequency -Domain Interpretation of PI Control
Acting as a low-pass filter, the PI controller slows the system's response and extends settling times. This requires...
Time and frequency -Domain Interpretation of Phase-lead Control
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
Time and frequency -Domain Interpretation of Phase-lag Control
Phase-lag controllers do not place a pole at zero, but instead influence the steady-state error by amplifying any...

