Corneal biomechanical properties and potential influencing factors in varying degrees of myopia
Yunxiao Sun1, Yiqin Guo1, Ruiqi Pang1
1Beijing Ophthalmology and Visual Sciences Key Lab, Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, No. 1 Dongjiaominxiang Street, Dongcheng District, Beijing, 100730, China.
Abstract:
To compare the corneal biomechanical parameters measured by Corvis ST in subjects with varying degrees of myopia. And the factors that may affect corneal biomechanical properties were also investigated. Participants in this prospective cross-sectional study were classified into three groups according to spherical equivalent (SE) and axial length (AL): Non-myopia (NM, SE > - 0.50 D and AL < 26 mm), Mild-to-moderate myopia (MM, - 6.00 D < SE ≤ - 0.50 D and AL < 26 mm), high myopia (HM, SE ≤ - 6.00 D or AL ≥ 26 mm). Ten corneal biomechanical parameters were finally included. Linear mixed-effects model accounting for using both eyes in the same participant was carried out to evaluate how the corneal biomechanical parameter was influenced by varying degrees of myopia after adjusting for biomechanically corrected intraocular pressure (bIOP) and central corneal thickness (CCT). Further, multiple linear regression was performed to explore the correlation between corneal biomechanical parameter and SE, AL, bIOP or CCT. A total of 304 eyes from 224 healthy myopic subjects were recorded. There were 95 eyes with NM, 122 eyes with MM, and 87 eyes with HM. After adjusting for bIOP and CCT, eyes with high myopia showed shorter highest concavity time (HC-time, p = 0.025), greater peak distance (PD, p = 0.001), greater deflection amplitude (DA-Max, p = 0.002), smaller whole eye movement (WEM-Max, p < 0.001) and reduced stiffness parameter (SP-A1, p < 0.001). Multiple regression analysis showed that five parameters (HC-time, p < 0.001; PD, p < 0.001; DA-Max, p = 0.001; WEM-Max, p < 0.001; and SP-A1, p < 0.001) of Corvis ST were significantly correlated with AL, and one parameter (Corvis biomechanical index, p = 0.016) has significant relationship with SE. With the increase of myopia, significant changes in several corneal biomechanical parameters indicated a progressive decrease in corneal stiffness, independent of bIOP and CCT. Corneal biomechanical parameters may be predictors of scleral mechanical strength in high myopia, which has certain application value in clinical management of myopia.
More Related Videos
05:46Author Spotlight: Advancements in Refractive Surgical Correction for Presbyopia and Exploring Postoperative Visual Acuity
Published on: September 20, 2024
05:56Scleral Cross-linking Using Riboflavin and Ultraviolet-A Radiation for Prevention of Axial Myopia in a Rabbit Model
Published on: April 3, 2016
Related Concept Videos
Focusing of Light in the Eye
Glaucoma: Overview
Accessory Structures of the Eye