Development, optimization and validation of automated volatile organic compound data analysis using an on-line
Fanny Bachelier1, Mathilde Mascles2, Max R McGillen3
1Institut de Combustion, Aérothermique, Réactivité et Environnement (ICARE-CNRS), 1C, av. de la Recherche Scientifique CS 50060 - 45071, Orléans Cedex 2, France; Chromatotec, 15 rue d'Artiguelongue, Saint-Antoine 33240, France.
Abstract:
Because of their major role in indoor and outdoor air pollution, even at trace levels, VOCs are of great interest, and their monitoring requires sensitive analytical instruments. Several techniques are commonly used, such as portable sensors, Proton Transfer Reaction Mass Spectrometry (PTR-MS) and Thermal Desorption Gas Chromatography (TD-GC). The latter is widely used off- and on-line with Flame Ionization Detectors (FID) or Mass Spectrometers (MS). Given the large number of molecules detected per chromatogram, the data generated by these monitoring techniques are usually checked and reprocessed manually. This process is extremely time consuming and could result in human error. The challenge is to provide reliable results as quickly as possible. In this study, the performances of an on-line TD-GC system with dual detection FID and MS were tested. The Method Detection Limits (MDL), linearities and accuracies of 60 VOCs (alkanes, aromatics, oxygenated and halogenated) were calculated both for FID and MS detectors. The MDLs and accuracies ranged from 0.006 to 0.618 ppbv and from 77 % to 100 % for FID, and from 0.018 to 0.760 ppbv and from 80 % to 100 % for MS. Both detectors showed good complementarity and allowed the development of two programs to facilitate data analysis. These algorithms were designed to autonomously select optimal results between FID and MS detectors, and were evaluated for outdoor and indoor measurement conditions. Measuring VOCs in field campaigns is challenging, and it is anticipated that these programs could be extended to other types of dual-detector systems or for the comparison of data from different calibrated instruments.
More Related Videos
08:43PTR-ToF-MS Coupled with an Automated Sampling System and Tailored Data Analysis for Food Studies: Bioprocess Monitoring, Screening and Nose-space Analysis
Published on: May 11, 2017
10:22Split Point Analysis and Uncertainty Quantification of Thermal-Optical Organic/Elemental Carbon Measurements
Published on: September 7, 2019
Related Concept Videos
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...