Related Experiment Video
Updated: Jun 14, 2025

Optimized Staining and Proliferation Modeling Methods for Cell Division Monitoring using Cell Tracking Dyes
Published on: December 13, 2012
Dihydrorhodamine-123 flow cytometry method: time for substantial revision in technical procedure.
Mahdi Zavvar1,2, Sina Zargaran2,3, Hamed Baghdadi2,4
1Department of Medical Laboratory Sciences, School of Allied Medical Sciences, Tehran University of Medical Sciences, Tehran, Iran.
Optimizing the dihydrorhodamine 123 assay for reactive oxygen species measurement requires careful control of preanalytical and analytical variables. Standardizing these factors ensures reliable results for diagnosing chronic granulomatous disease.
Area of Science:
- Immunology
- Cellular Biology
- Diagnostic Assays
Background:
- The dihydrorhodamine 123 assay is a key method for measuring intracellular reactive oxygen species (ROS) in neutrophils.
- This assay is crucial for diagnosing chronic granulomatous disease (CGD).
- Numerous preanalytical and analytical variables can impact the assay's reliability.
Purpose of the Study:
- To identify optimal conditions for the dihydrorhodamine 123 assay.
- To establish standard operating procedures for reliable ROS measurement.
- To compare preanalytical and analytical phases influencing test outcomes.
Main Methods:
- Investigated the impact of different anticoagulants on assay results.
- Assessed the effect of sample transport and storage temperatures (4°C vs. 24°C).
- Evaluated the influence of test prime run time, solution concentrations, and incubation temperatures (24°C vs. 37°C).
Main Results:
- Specific anticoagulants and temperature conditions significantly affected ROS production measurements.
- Incubation temperature and sample handling protocols demonstrated a notable impact on assay sensitivity.
- Optimized parameters were identified to enhance assay precision and accuracy.
Conclusions:
- Standardizing preanalytical and analytical steps is essential for reproducible dihydrorhodamine 123 assay results.
- Implementing defined operating procedures based on these findings will improve diagnostic accuracy for CGD.
- Further research may refine these parameters for even greater reliability.
More Related Videos
05:16Author Spotlight: High-Throughput Measurement of Intracellular ROS Levels in Hepatocellular Lines
Published on: January 19, 2024
14:25Quantification of Reactive Oxygen Species Using 2′,7′-Dichlorofluorescein Diacetate Probe and Flow-Cytometry in Müller Glial Cells
Published on: May 13, 2022