Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Multireflecting gas chromatography-multireflecting time-of-flight mass spectrometer with high dynamic range
Aleksey V Vorobyev1, Yury I Khasin1, Vasily V Makarov1
1Mass Spectrometry Consulting Ltd, MSC-CG, Bar, Montenegro.
Abstract:
Gas chromatography-mass spectrometry (GC-MS) is a cornerstone technique for analyses of volatile and semivolatile compounds, constantly evolving to meet new challenges. The adoption of time-of-flight mass spectrometers (TOFMS) has enhanced GC-MS with faster spectral acquisition and broader mass coverage, enabling rapid GC separations. Multireflecting TOFMS (MRT) further improves resolution compared to traditional single-reflecting TOFMS, facilitating the detection of minor analytes within complex matrices. This paper presents a significant improvement in MRT sensitivity and dynamic range achieved through an ion beam compression within the ion guide and the use of a conventionally oriented orthogonal accelerator. Sensitivity is improved to 100 000 ion/pg at a resolution of R = 25,000, enabling the detection of low fg analyte quantities within 3 μg of matrix material into MS. The demonstrated linear dynamic range exceeding 6 orders of magnitude potentially enables even deeper exploration of complex mixtures with a bench top instrument.
More Related Videos
08:43PTR-ToF-MS Coupled with an Automated Sampling System and Tailored Data Analysis for Food Studies: Bioprocess Monitoring, Screening and Nose-space Analysis
Published on: May 11, 2017
11:00Untargeted Metabolomics from Biological Sources Using Ultraperformance Liquid Chromatography-High Resolution Mass Spectrometry UPLC-HRMS
Published on: May 20, 2013
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Types of Detectors-II
Tandem Mass Spectrometry
Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called collision-induced...
High-Resolution Mass Spectrometry (HRMS)
Mass Analyzers: Common Types