Related Experiment Video
Updated: Jun 13, 2025

09:23
Effect of Fluorescent Proteins on Fusion Partners Using Polyglutamine Toxicity Assays in Yeast
Published on: November 28, 2018
6.8K
Rapid Fluorescence Assay for Polyphosphate in Yeast Extracts Using JC-D7
Alexander Deitert1, Jana Fees1, Anna Mertens1
1Institute of Applied Microbiology-iAMB, Aachen Biology and Biotechnology-ABBt, RWTH Aachen University, Aachen, Germany.
Yeast (Chichester, England)
|September 12, 2024
Summary
A new fluorescent dye, JC-D7, offers a simple method for semi-quantifying polyphosphate (polyP) in yeast extracts. This assay aids in screening microbes for enhanced biotechnological polyP production and sustainable phosphorus use.
Area of Science:
- Biochemistry
- Microbiology
- Analytical Chemistry
Background:
- Polyphosphate (polyP) is a ubiquitous molecule with diverse cellular roles and industrial applications.
- Accurate polyP quantification remains analytically challenging, with 31P NMR as the current gold standard.
- Existing methods limit high-throughput screening for polyP production.
Purpose of the Study:
- To develop a simple, sensitive, and cost-effective method for semi-quantitative polyP analysis.
- To evaluate the fluorescent dye JC-D7 for polyP detection in microbial extracts.
- To enable high-throughput screening of polyP production in yeast.
Main Methods:
- A novel staining method using the fluorescent dye JC-D7 was developed for polyP evaluation.
- The fluorescence response of JC-D7 was analyzed concerning polyP concentration and chain length.
- Interference from inorganic phosphate, trace elements, and mineral salts was assessed.
- The assay was validated using yeast extracts from strains with altered (poly)phosphate homeostasis.
Main Results:
- JC-D7 fluorescence correlated with polyP concentration (0.5–500 µg/mL) and chain length, enabling semi-quantification.
- The dye showed no significant interference from inorganic phosphate up to 50 mM.
- Certain trace elements and toxic mineral salts diminished JC-D7 fluorescence, impacting polyP-metal complex analysis.
- The assay proved robust and sensitive for detecting polyP in yeast extracts.
Conclusions:
- JC-D7 staining provides a simple and sensitive method for semi-quantitative polyP detection in yeast and potentially other microbes.
- The assay's simplicity facilitates high-throughput screening for enhanced biotechnological polyP production.
- This method contributes to sustainable phosphorus utilization by optimizing polyP bioproduction.