Normal Saline Versus Hypertonic Saline for Airway STENT Maintenance: SALTY STENT Study
Bertin D Salguero1, Greta Joy1, Christian M Lo Cascio1
1Division of Pulmonary, Critical Care and Sleep Medicine, Icahn School of Medicine, Mount Sinai.
Background:
Mucus plugging is a common complication of airway stenting. There is no data or guidance on the best airway hygiene regimen and consequently wide practice variation exists.
Methods:
This single-center, nonblinded, randomized, pilot study aims to evaluate the effectiveness and safety of nebulized 3% saline (3%S) versus normal saline (NS) in reducing the incidence of mucus plugging in adult patients that undergo central airway stent placement. Patients were enrolled immediately after stent placement and randomized to nebulized 3%S or NS (3 mL) 3 times a day. Patients were scheduled for surveillance bronchoscopy in 4 to 6 weeks. Unscheduled bronchoscopies due to symptomatic mucus plugging were recorded.
Results:
From December 2022 to March 2024, 37 patients were screened, and 35 were enrolled. Four in the 3%S and 8 in the NS group did not undergo a surveillance bronchoscopy and were excluded from the final analysis. During surveillance bronchoscopy for the 3%S (n=13) and NS (n=10) groups, obstructive mucus plugging was noted in 7.7% versus 40%, granulation requiring intervention in 7.7% versus 10%, and >25% circumferential biofilm in 0% versus 30%, respectively. In the 3%S versus NS groups, 0% versus 20% of patients required an unscheduled bronchoscopy due to mucus plugging. There were no side effects reported with the daily use of 3%S or NS.
Conclusion:
Nebulized 3%S is safe and may be equally or more effective than NS in preventing obstructive mucus plugging in patients who undergo airway stenting. A larger blinded randomized controlled trial is necessary to confirm this finding.
Related Concept Videos
Tracheostomy Suctioning II: Procedure
Suctioning the Nasopharyngeal Airway
Equipment Required
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Epistaxis
Etiology
Possible causes of this condition include high blood pressure, trauma, low humidity, upper respiratory tract infections, allergies, foreign bodies, nasal inhalation of corticosteroids or illicit drugs, excessive use of decongestant nasal sprays, facial or nasal surgery, anatomic malformation, tumors, or systemic...
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Tracheostomy Suctioning I: Pre-Procedural Steps
Equipment Required
First, gather all necessary equipment: a sterile suction catheter, a sterile disposable container, sterile gloves, a towel or...