A Novel Rescue Technique for Difficult Intubation and Difficult Ventilation
Published on: January 17, 2011
Ventilator variables predicting extubation readiness in extremely premature infants with prolonged mechanical
Truong An Nguyen1, Josef Matoušek1, Aleš Kuběna2
1Department of Gynaecology, Obstetrics and Neonatology, First Faculty of Medicine Charles University and General University Hospital in Prague, Prague, Czech Republic.
Background:
The current generation of neonatal ventilators enables periodic storage of set, measured, and calculated ventilatory parameters.
Design:
Retrospective observational study.
Objectives:
To evaluate and identify the ventilatory, demographic, and clinical pre-extubation variables that are significant for estimating extubation readiness.
Methods:
Eligible subjects included premature infants <33 weeks of gestation weaned from mechanical ventilation (MV) lasting >24 h. A total of 16 relevant ventilator variables, each calculated from 288 data points over 24 h, together with eight demographic and three clinical pre-extubation variables, were used to create the generalized linear model (GLM) for a binary outcome and the Cox proportional hazards model for time-to-event analysis. The achievement of a 120-h period without reintubation was defined as a successful extubation attempt (EA) within the binary outcome.
Results:
We evaluated 149 EAs in 81 infants with a median (interquartile range) gestational age of 25+2 (24+3-26+1) weeks. Of this, 90 EAs (60%) were successful while 59 (40%) failed. GLM identified dynamic compliance per kilogram, percentage of spontaneous minute ventilation, and postmenstrual age as significant independent positive variables. Conversely, dynamic compliance variability emerged as a significant independent negative variable for extubation success. This model enabled the creation of a probability estimator for extubation success with a good proportion of sensitivity and specificity (80% and 73% for a cut-off of 60%, respectively).
Conclusions:
Ventilator variables reflecting lung mechanical properties and the ability to spontaneously breathe during MV contribute to better prediction of extubation readiness in extremely premature infants with chronic lung disease.
Related Concept Videos
Mechanical Ventilation I: Indication and Settings
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...