Development and external validation of a novel modality for rapid recognition of aortic dissection based on
Jing-Chao Luo1, Yi-Jie Zhang1, Ying Niu2
1Cardiac Intensive Care Center, Zhongshan Hospital, Fudan University, Shanghai, China.
Background:
Aortic dissection (AD) is a life-threatening cardiovascular emergency that is often misdiagnosed as other chest pain conditions. Physiologically, AD may cause abnormalities in peripheral blood flow, which can be detected using pulse oximetry waveforms.
Purpose:
This study aimed to assess the feasibility of identifying AD based on pulse oximetry waveforms and to highlight the key waveform features that play a crucial role in this diagnostic method.
Methods:
This prospective study employed high-risk chest pain cohorts from two emergency departments. The initial cohort was enriched with AD patients (n = 258, 47% AD) for model development, while the second cohort consisted of chest pain patients awaiting angiography (n = 71, 25% AD) and was used for external validation. Pulse oximetry waveforms from the four extremities were collected for each patient. After data preprocessing, a recognition model based on the random forest algorithm was trained using patients' gender, age, and waveform difference features extracted from the pulse oximetry waveforms. The performance of the model was evaluated using receiver operating characteristic (ROC) curve analysis and decision curve analysis (DCA). The importance of features was also assessed using Shapley Value and Gini importance.
Results:
The model demonstrated strong performance in identifying AD in both the training and external validation sets. In the training set, the model achieved an area under the ROC curve of 0.979 (95% CI: 0.961-0.990), sensitivity of 0.918 (95% CI: 0.873-0.955), specificity of 0.949 (95% CI: 0.912-0.985), and accuracy of 0.933 (95% CI: 0.904-0.959). In the external validation set, the model attained an area under the ROC curve of 0.855 (95% CI: 0.720-0.965), sensitivity of 0.889 (95% CI: 0.722-1.000), specificity of 0.698 (95% CI: 0.566-0.812), and accuracy of 0.794 (95% CI: 0.672-0.878). Decision curve analysis (DCA) further showed that the model provided a substantial net benefit for identifying AD. The median mean and median variance of the four limbs' signals were the most influential features in the recognition model.
Conclusions:
This study demonstrated the feasibility and strong performance of identifying AD based on peripheral pulse oximetry waveforms in high-risk chest pain populations in the emergency setting. The findings also provided valuable insights for future human fluid dynamics simulations to elucidate the impact of AD on blood flow in greater detail.
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Pulse
The pulse serves as a clinical...
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Special considerations while measuring pulse