Related Experiment Video
Updated: Jun 13, 2025

Preparation of Aligned Steel Fiber Reinforced Cementitious Composite and Its Flexural Behavior
Published on: June 27, 2018
Experimental Study on Shear Strengthening of Reinforced Concrete Beams by Fabric-Reinforced Cementitious Matrix
Chanseo Jung1, Yujae Seo2, Junseo Hong1
1Department of Architecture and Architectural Engineering, Hankyong National University, Jungang-ro 327, Anseong 17579, Republic of Korea.
Abstract:
In this study, an experiment was conducted to investigate the shear performance of reinforced concrete (RC) beams strengthened using fabric-reinforced cementitious matrices (FRCM). Four reinforced concrete beams, including a control specimen, were fabricated, and the shear strengthening effect of the FRCM was investigated on eight shear specimens, with the strengthening type and shear reinforcement as key variables. In particular, the digital image correlation (DIC) technique was applied to closely analyze the deformation of reinforced concrete beams subjected to shear forces. The average shear strain-shear stress curve of each specimen was derived, and the contributions of shear and bending to the vertical deflection and the change in the principal strain angle with increasing shear force were analyzed. The experiment results showed that all specimens failed with diagonal cracks within the shear span. In the specimens without shear reinforcement, the shear strength increased by up to 65% according to the FRCM strengthening, while in the specimens with shear reinforcement, only the sided bond strengthened specimen showed a strength increase of 16% compared to the control specimen. Based on displacement data of the DIC, it was confirmed that FRCM strengthening can control the deformation of the RC beam. To evaluate the shear strength of the FRCM-strengthened RC beams, a shear strength model was proposed by considering the contributions of the concrete section, shear reinforcement, and FRCM. The proposed model was capable of reasonably evaluating the shear strength of RC beams strengthened with FRCM, considering the shear contribution of FRCM and bond capacity between FRCM and concrete substrate, in which the shear strength of specimens was underestimated by 28% to 35%.
Related Concept Videos
Fiber Reinforced Concrete
Reinforcements in Concrete
Design Example: Distributing Reinforcements in Concrete Sections
Shearing Stresses in a Beam: Problem Solving
Tensile Strength Considerations of Concrete
The dimensions and shape of a concrete specimen...
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...