Compressor fault diagnosis and result visualization based on fusion of vision transformer and improved residual
Xianling Duan1, Shaolin Hu2, Sijing Wang3
1School of Information and Control Engineering Jilin Institute of Chemical Technology, Jilin, Jilin, 132000, China.
Abstract:
Compressors are important production equipment in the petrochemical industry, and the accuracy of their fault diagnosis is critical. In order to detect and diagnose compressor equipment faults in a timely manner, this paper constructs a deep residual shrinkage visual network (DRS-ViT). The network comprises a modified residual network (ResNet) and a vision transformer (ViT). The obtained compressor vibration signals were transformed into gram angle sum field (GASF) plots using gram angle field (GAF). The resulting image is the passed through a modified ResNet network to extract initial features. The extracted feature images are subsequently input into the ViT model for fault classification. The experimental results demonstrate that the fault diagnosis accuracy achieved by the DRS-ViT model is 99.5 %. The visualization of the model indicates that it can effectively identify the fault points. The validity and robustness of the DRS-ViT model are confirmed through comparison and analysis with various models.
More Related Videos
Related Concept Videos
Energy Losses in Transformers
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
Transformers in Distribution System
Distribution substation transformers come in various ratings and typically use mineral oil for insulation and cooling. To prevent moisture and air from entering the oil, some transformers use an inert gas like nitrogen to fill the...
The Ideal Transformer
Ampere's Law forms the basis of understanding the magnetic field within the transformer. It states that the integral of the magnetic field intensity's...
Three-Winding Transformers
In the per-unit equivalent circuit of a grounded Y-Y three-phase...
Types Of Transformers
If the ratio of the number of turns in the secondary winding to that of the primary winding is greater than one, then the transformer is said to be a step-up transformer. In a step-up transformer, the voltage at the secondary winding is greater than the voltage applied at the primary winding.
However, if this ratio is less than one, the transformer is said to be a step-down...
Instrument Transformers