Related Experiment Video
Updated: Jun 13, 2025

Tilt Testing with Combined Lower Body Negative Pressure: a "Gold Standard" for Measuring Orthostatic Tolerance
Published on: March 21, 2013
Unattended versus conventional blood pressure measurements in hospitalized hypertensive patients
1Department of Hypertension, Ruijin Hospital, Shanghai Jiaotong University School of Medicine.
Background:
This study aims to compare the differences between unattended and conventional blood pressure measurements in hospitalized hypertensive patients.
Methods:
In fall of 2019, hypertensive patients at Ruijin Hospital underwent two rounds of unattended and conventional (nurse-monitored) blood pressure measurement. Both rounds used the same electronic blood pressure monitor with measurements taken three times, 30 s apart. Comparison was made using intra-class correlation coefficients, Bland-Altman plots, paired t -tests, etc.
Results:
Among the 92 subjects in the study, the median age was 50 years old, with women accounting for 33.7%. Among the subjects, the median duration of hypertension was 8.0 years. The prevalence of diabetes, coronary heart disease, and stroke were 26.1%, 5.4%, and 6.5%, respectively. Whether unattended or conventional measurements were taken first, the average blood pressure measured first was slightly higher than the one measured later, but the difference was within 1-2 mmHg. Except that the average DBP during the round of conventional blood pressure measurements was significantly reduced by 1.6 mmHg compared to the conventional DBP, there were no other significant differences. Subgroup analysis by age, gender, BMI, and diabetes showed no significant difference in blood pressure measurement results between unattended and conventional methods.
Conclusion:
No significant difference was observed between unattended and conventional methods of blood pressure measurement in hospitalized hypertensive patients. Unattended blood pressure measurement can be adopted as the current standard for blood pressure management in hospitalized patients.
More Related Videos
07:35Simultaneous Electrocardiography Recording and Invasive Blood Pressure Measurement in Rats
Published on: January 31, 2019
09:38Femoral Arterial and Venous Catheterization for Blood Sampling, Drug Administration and Conscious Blood Pressure and Heart Rate Measurements
Published on: January 24, 2012
Related Concept Videos
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Measurement of Blood Pressure
Assessment of blood pressure in brachial artery(two-step method)
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Pre-Procedural Guidelines for Assessing Blood Pressure