Published on: November 6, 2015
A Comprehensive Review on a Prosthetic Finger Fabrication Approach: Clinical Rest Position (CRP) vs Palms and Fingers
Arunoday Kumar1, Thingujam Debica1, Manjula Das2
1Department of Prosthodontics and Crown and Bridge, Dental College, Regional Institute of Medical Sciences (RIMS), Imphal, IND.
Fabricating prosthetic fingers in the clinical rest position (CRP) offers better aesthetics and function compared to the extended position (PFE). This approach provides a promising alternative for improved prosthetic finger outcomes.
Area of Science:
- Prosthodontics
- Biomedical Engineering
- Reconstructive Surgery
Background:
- Effective prosthetic fingers require precise planning and fabrication for aesthetics and passive function.
- Prosthetic outcomes depend on retention and mimicking natural finger contours.
- Current literature predominantly focuses on fabrication in the palms and fingers extended (PFE) position.
Purpose of the Study:
- To compare prosthetic finger fabrication techniques in clinical rest position (CRP) versus PFE.
- To evaluate aesthetics and passive function of prostheses fabricated in CRP and PFE.
- To determine the superior approach for prosthetic finger design and outcomes.
Main Methods:
- Systematic review of 20 articles from national and international journals over 20 years.
- Analysis of fabrication techniques for prosthetic fingers in CRP and PFE.
- Examination of aesthetic and passive functional outcomes for both fabrication positions.
Main Results:
- Most existing literature addresses PFE fabrication, with limited focus on CRP.
- Prosthetic fingers fabricated in CRP demonstrate superior aesthetic appearance.
- CRP fabrication also yields improved passive functional outcomes compared to PFE.
Conclusions:
- Prosthetic finger fabrication in CRP is a promising alternative to PFE.
- CRP offers enhanced aesthetic and partial functional benefits.
- Further research is needed to validate these findings and advance prosthetic development.
Related Concept Videos
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Pre-Procedural Guidelines for Assessing Blood Pressure
Muscles of the Forearm that Move the Hand and Fingers
Anterior Compartment
The anterior compartment muscles originate from the humerus. They primarily function as flexors and are also known as flexor muscles. They typically insert on the carpals, metacarpals, and phalanges. The superficial layer includes the flexor carpi radialis,...
Physical Assessment of the Respiratory Tract II: Palpation
Thoracic Palpation
Thoracic palpation detects tenderness, masses, lesions, respiratory excursions, and vocal fremitus. The nurse assesses...
Assessment of the Abdomen III: Palpation
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...