Related Experiment Video
Updated: Jun 12, 2025

An Educational Video Demonstration of How to Prone a Critically Ill Intubated Patient
Published on: November 30, 2022
Incidence of Pressure Injuries in Patients at Risk Using a Powered Alternating Pressure Air Mattress: A
Sylvie Meaume1,2,3, Renaud Urbinelli1,2,3, Marc Marty1,2,3
1Sylvie Meaume, MD, Rothschild Hospital-Geriatric Department and Wound Care Unit, Assistance Publique hôpitaux de Paris, Paris, France.
Purpose:
The aim of the study was to determine the clinical value of using a powered alternating pressure air mattress (P-APAM) in the prevention of pressure injury (PI) in patients at medium to high risk.
Design:
Noncomparative, observational study.
Subjects And Setting:
The sample comprised 86 patients who were >18 years old, were classified as having medium to high risk of PI, had no PI at baseline, and were lying more than 15 hours a day on a specific P-APAM. Data were collected between September 2018 and July 2019, in 4 nursing homes, and 1 long-term care geriatrics hospital department in France.
Methods:
In addition to guideline-based care for PI prevention, patients were followed up for 35 days following placement on the P-APAM. The main outcome was the percentage of patients who developed between day 0 and day 35 at least 1 PI of at least stage 2 on the sacrum, spine, or heel. Secondary outcomes were patient assessments of comfort, caregiver satisfaction, mattress noise level, and mattress safety.
Results:
No patients experienced a PI (incidence = 0%; 95% confidence interval, 0.00%-4.28%). Patients were satisfied or very satisfied with the mattress in most cases in terms of comfort (77.9%) and stability (73.0%). Patients also rated the noise level of the mattress as satisfactory or very satisfactory in all cases (100%).
Conclusion:
When combined with guideline-based PI prevention measures, use of the P-APAM was associated with a low incidence of PI.
Related Concept Videos
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Measurement of Blood Pressure
Healthcare Associated Infections II: Preventive Measures
The best practices for preventing healthcare-associated infections include hand hygiene, patient risk...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...

