Related Experiment Video
Updated: Jun 12, 2025

Autoradiography as a Simple and Powerful Method for Visualization and Characterization of Pharmacological Targets
Published on: March 12, 2019
Usefulness and limitations of various detector systems for estimation of131I thyroid activity following an RN event
Martin Hjellström1, Frida Westerbergh1, Eva Forssell-Aronsson1,2
1Department of Medical Radiation Sciences, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.
Abstract:
Following a radiological or nuclear (RN) event, rapid measurement of131I in members of the public is of utmost importance, and much equipment is needed for a high throughput. In this study, three gamma cameras (GCs), two thyroid uptake meters (TUMs) and one whole-body counter (WBC) were calibrated for activity measurements of131I in the thyroid. Minimum detectable activity was derived for the GCs, the TUMs and the WBC giving that a committed effective dose (CED) in the interval 2.0-85μSv, 13-700μSv and 0.52-6.4μSv, and thyroid absorbed doses in the interval 0.075-2.1 mGy, 0.48-17 mGy, and 0.020-0.15 mGy, respectively, can be assessed for children, adolescents, and adults. These numbers are based on 10 min measurement, performed at 1, 3 and 7 d after intake, and the CED includes intake by ingestion and inhalation of aerosols Type F, with an activity median aerodynamic diameter of 1μm. For a fractional signal loss of 63% due to dead time, a CED up to 2.0, 84 and 3.6 Sv and thyroid absorbed dose up to 47 Gy, 2000 Gy and 88 Gy for the three systems, respectively, can be assessed for children and intake by ingestion as a worst-case scenario in terms of CED, measured 7 d after intake. This study demonstrates the potential and limitations of using equipment readily available at larger hospitals for estimation of131I content in thyroid, which could increase the measurement capability following an RN event.
More Related Videos
14:19A Basic Positron Emission Tomography System Constructed to Locate a Radioactive Source in a Bi-dimensional Space
Published on: February 1, 2016
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Biological Effects of Radiation
Radiological Investigation I: X-ray and CT
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Isotopes and Radioisotopes
An isotope containing...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...