Lens Thickness in Infants and Children with Cataracts
Libby Wei1, Taylor Kolosky1, Sarah Byun1
1Department of Ophthalmology and Visual Sciences, University of Maryland School of Medicine, Baltimore, Maryland.
Ophthalmology Science
|September 25, 2024
Summary
Infants with congenital cataracts have thinner lenses. Ultrasound biomicroscopy (UBM) effectively measures lens thickness, revealing that thinner lenses are significantly associated with an increased risk of pediatric cataract.
Area of Science:
- Ophthalmology
- Pediatric ophthalmology
- Biomedical imaging
Background:
- Congenital cataracts are a leading cause of visual impairment in infants.
- Early detection and understanding of risk factors are crucial for timely intervention.
- Lens thickness has not been extensively studied as a potential indicator in pediatric cataracts.
Purpose of the Study:
- To determine the association between lens thickness and congenital cataract in children aged 0-5 years.
- To evaluate the feasibility of measuring lens thickness using ultrasound biomicroscopy (UBM).
Main Methods:
- A prospective, multicenter, case-control study was conducted.
- 118 participants (171 eyes) aged 0-5 years were enrolled.
- Lens thickness was measured using ultrasound biomicroscopy (UBM) on 342 images.
Main Results:
- Mean lens thickness was 3.60 ± 0.17 mm in non-cataract eyes versus 3.16 ± 0.61 mm in cataract eyes (P < 0.0001).
- Lens thickness <3.5 mm was significantly associated with increased odds of cataract (adjusted OR = 5.99) in infants 0-7 months old.
- Lens thickness was also significantly associated with cataract laterality in this age group (P < 0.0001).
Conclusions:
- Quantitative UBM is a viable method for assessing lens thickness in infants and children with congenital cataracts.
- Infants with congenital cataracts exhibit thinner lenses compared to controls.
- Abnormal lens thickness is a significant risk factor associated with pediatric cataract.
Related Concept Videos
Focusing of Light in the Eye
2.6K
Light rays enter the eye through the cornea, a transparent dome-shaped tissue that is the eye's outermost layer. The cornea bends or refracts, light rays traveling to the pupil. The shape of the cornea determines how much of the light is bent and whether the image will be focused correctly on the retina at the back of the eye. Once the light has passed through both refraction layers, it converges into a single focal point onto a small area. This is where photoreceptors start transforming...
2.6K
Photoreceptors and Visual Pathways
5.9K
At the molecular level, visual signals trigger transformations in photopigment molecules, resulting in changes in the photoreceptor cell's membrane potential. The photon's energy level is denoted by its wavelength, with each specific wavelength of visible light associated with a distinct color. The spectral range of visible light, classified as electromagnetic radiation, spans from 380 to 720 nm. Electromagnetic radiation wavelengths exceeding 720 nm fall under the infrared category,...
5.9K
Glaucoma: Overview
528
Glaucoma is an eye condition characterized by increased intraocular pressure that damages the retina and optic nerve, leading to irreversible blindness if left untreated. The human eye has various components, including the cornea, iris, pupil, lens, and optic nerve. Aqueous humor is secreted by the epithelium of the ciliary body in the posterior chamber and flows through the trabecular meshwork and canal of Schlemm, maintaining normal intraocular pressure. The trabecular meshwork and the canal...
528